Overtorque detection 2 functions the same as overtorque/undertorque detection 1 (
L06.01
), except that “OT2/UT2”
is displayed on the keypad instead.
Parameter
Name
Function
Range
Default
L06.05
Torque Detection 2 Level
Torque Detection 2 Level
0–300%
150
L06.06
Torque Detection 2 Time
Torque Detection 2 Time
0.0–10.0 sec
0.1
L06.08
Mechanical Weakening Detection
Selection
Determines the action to take during
and after detection
00–08
00
00 Disabled
01 Speed (signed) > L06.09;
Continue Running (Alarm)
02 Speed (unsigned) > L06.09;
Continue Running (Alarm)
03 Speed (signed) > L06.09; Stop
(Protection)
04 Speed (unsigned) > L06.09;
Stop (Protection)
05 Speed (signed) < L06.09;
Continue Running (Alarm)
06 Speed (unsigned) < L06.09;
Continue Running (Alarm)
07 Speed (signed) < L06.09; Stop
(Protection)
08 Speed (unsigned) < L06.09;
Stop (Protection)
L06.09
Mechanical Weakening Detection
Speed Level
Sets the speed for Load Weakening
Detection
-110.0–110.0%
110.0
L06.10
Mechanical Weakening Detection
Time
Sets the time required for Mechanical
Weakening to be detected before
triggering parameter L06.08.
0.0–10.0 sec
0.1
L06.11
Mechanical Weakening Detection
Start Time
Mechanical Weakening Detection is
triggered when the cumulative
operation time exceeds U04.01.
0–65535 hr
0
Содержание IMPULSE G+ Mini
Страница 15: ...IMPULSE G Mini Technical Manual November 2020 Page 15 Figure 2 1 Long Time Storage...
Страница 17: ...IMPULSE G Mini Technical Manual November 2020 Page 17 Figure 2 2 Diagram A Figure 2 3 Diagram B...
Страница 18: ...IMPULSE G Mini Technical Manual November 2020 Page 18 Figure 2 4 Diagram C...
Страница 56: ...IMPULSE G Mini Technical Manual November 2020 Page 56 Figure 5 8 DC Injection Brake Time Calculation...
Страница 181: ......
Страница 182: ...IMPULSE G Mini Adjustable Frequency Crane Controls Technical Manual November 2020...