IMPULSE
®
•G+ Mini Technical Manual
November 2020
Page 133
Table 5-21: Motor Control Monitor
Monitor
Name
Function
Units
U06.01
Motor Secondary Current (lq) Displays the value of the motor secondary current (Iq). Motor rated
secondary current is 100%.
%
U06.02
Motor Excitation Current (ld)
Displays the value calculated for the motor excitation current (Id).
Motor rated secondary current is 100%.
%
U06.03
ASR Input
Displays the input value when using ASR control.
%
U06.04
ASR Output
Displays the output value when using ASR control.
%
U06.05
Output Voltage Reference
(Vq)
Output voltage reference (Vq) for the q-axis.
V
U06.06
Output Voltage Reference
(Vd)
Output voltage reference (Vd) for the d-axis.
V
U06.07
ACR (q) Output
Displays the output value for current control relative to motor
secondary current (q-axis).
%
U06.08
ACR (d) Output
Displays the output value for current control relative to motor
secondary current (d-axis).
%
U06.20
Frequency Reference Bias
(Up/Down2)
Displays the bias value used to adjust the frequency reference.
%
U06.36
GAIA Communication Error
Count of communication errors by the GAIA. This monitor is cleared
at power-down.
-
U06.37
LUNA Communication Error
Count of communication errors by the GAIA. This monitor is cleared
at power-down.
-
U06.38
Option Card Error
Count of communication errors between VFD and option card. This
monitor is cleared at power-down.
-
Содержание IMPULSE G+ Mini
Страница 15: ...IMPULSE G Mini Technical Manual November 2020 Page 15 Figure 2 1 Long Time Storage...
Страница 17: ...IMPULSE G Mini Technical Manual November 2020 Page 17 Figure 2 2 Diagram A Figure 2 3 Diagram B...
Страница 18: ...IMPULSE G Mini Technical Manual November 2020 Page 18 Figure 2 4 Diagram C...
Страница 56: ...IMPULSE G Mini Technical Manual November 2020 Page 56 Figure 5 8 DC Injection Brake Time Calculation...
Страница 181: ......
Страница 182: ...IMPULSE G Mini Adjustable Frequency Crane Controls Technical Manual November 2020...