5.4 Motor Parameters
Motor data such as full load amps and V/f patterns are selected with the following parameters. These parameters
include the ability to select and set up custom V/f patterns for the type of motor used.
•
E1 V/f Pattern
•
E2 Motor Set-up
5.4.1 Voltage/Frequency Pattern
Figure 5-26: E01.01 Input Voltage
•
Factory setting is 230 (230V units) or 460 (460V units).
•
Setting E01.11 ~ E01.13 = 0 means it's not used.
An OPE10 error will occur if the following conditions are not met:
E01.05
≥
E01.12
≥
E01.13
≥
E01.08
≥
E01.10
E01.04
≥
E01.11
≥
E01.06
≥
E01.07
≥
E01.09
The setting E01.01 adjusts the overvoltage level, braking transistor turn on level, and the stall prevention level
during deceleration.
Parameter
Name
Function
Range
Default
E01.01
Input Voltage
Sets input voltage
155–255/
310–510
230
460