Motor overload protection
UL recognized electronic thermal overload relay; field-programmable
Overcurrent protection level
200% of VFD rated current
Circuit protection
Ground fault and blown-fuse protection
Overvoltage protection level
Approximately 410VDC (230V Class), 820VDC (460V Class)
Undervoltage protection level
Approximately 190VDC (230V Class), 380VDC (460V Class)
Heatsink overtemperature
Thermostat trips at 184–249°F (90–121°C), dependent on VFD capacity
Torque limit selection
Limiting of Forward, Reverse, and Regen torques; selectable from 0–300%
Stall prevention
Functions for accel, decel, at-speed, and constant horsepower region
Other protection features
Lost output phase, failed-oscillator, mechanical overload, and internal braking
transistor failure.
DC bus voltage indication
Charge LED is on until DC bus voltage drops below 50VDC
Location
Indoors; requires protection from moisture, corrosive gases, and liquids
Ambient operating temperature
14° to 122°F (-10° to 50°C)
Storage temperature
-4° to 140°F (-20° to 60°C)
Humidity
95% relative; non-condensing
Vibration
10 to 20 Hz: 9.8 m/s
2
20 to 55 Hz: 5.9 m/s
2
Elevation
1,000 m and up to 3,000 m with derate. Derate 1% for every 100 m higher than 1,000 m.
Orientation
Install the VFD vertically to maintain maximum cooling effects.
Specification
Specification Value and Information for All Models
Содержание IMPULSE G+ Mini
Страница 15: ...IMPULSE G Mini Technical Manual November 2020 Page 15 Figure 2 1 Long Time Storage...
Страница 17: ...IMPULSE G Mini Technical Manual November 2020 Page 17 Figure 2 2 Diagram A Figure 2 3 Diagram B...
Страница 18: ...IMPULSE G Mini Technical Manual November 2020 Page 18 Figure 2 4 Diagram C...
Страница 56: ...IMPULSE G Mini Technical Manual November 2020 Page 56 Figure 5 8 DC Injection Brake Time Calculation...
Страница 181: ......
Страница 182: ...IMPULSE G Mini Adjustable Frequency Crane Controls Technical Manual November 2020...