5.8 Motor Tuning
•
N2 Automatic Frequency Regulator Tuning (OLV Only)
•
N6 Online Tuning
5.8.1 Automatic Frequency Regulator Tuning (OLV Only)
The Automatic Frequency Regulator (AFR) is used to achieve stability when a load is suddenly applied or removed
by calculating changes in the torque current feedback, and adjusting the output frequency accordingly.
If the system is hunting, increase the OLV Stabilization Level (N02.05) by one until the load stabilizes. Both D03.02
and N02.02 will be incremented or decremented accordingly.
Parameter
Name
Function
Range
Default
N02.01
Automatic Frequency
Regulator (AFR) Tuning
Automatic Frequency Regulator (AFR) Tuning
0.00–10.00
1.00
N02.02
AFR Detection Time
AFR Detection Time
0–2000ms
150
N02.03
AFR Time Constant
AFR Time Constant
0–2000ms
750
N02.05
OLV Stabilization Level
Sets the stabilization for OLV control
00–11, FF
08