Stuck coin failures
Automatic mismatch detection.
3.4.2 AUTOMATIC LINE INSULATION TEST (ALIT)
The automatic line insulation test (ALIT) scans lines to detect leakage to battery or ground and to report
unpressurized or under pressurized line cables. The ALIT is scheduled by means of recent change data. The
parameters that have to be filled in can be found in 235-118-2XX, View 8.1
OFFICE PARAMETERS. The ALIT
parameters can be temporarily changed by the input message
EXC:LIT?
. The next ALIT session will run at the
normally scheduled time. If a complete rescheduling of the ALIT is necessary, the parameters have to be changed
by means of recent change.
NOTE:
If you reschedule ALIT via the 8.1 RC/V, the scheduling change of ALIT will not take place until the next
ALIT session is over. After ALIT has run, the new parameters will take effect. To verify how the next ALIT
session has been scheduled, the
EXC:LIT,OPT=V;
input message can be used. Once an ALIT has
started, it will generate an autonomous start message.
When the switching module/switching module-2000 (SM/SM-2000)) is in minimum mode (for example, initialization),
the ALIT is skipped or suspended. This is indicated by an
EXC:LIT-SUSPEND
message. When the SM/SM-2000 is
fully initialized or in normal mode, ALITs run normally. A system overload can cause a suspension. A report
EXC:LIT-IN
is displayed when the ALIT resumes.
ALIT does not get suspended on a per SM/SM-2000 basis. However, ALIT can be suspended for an individual unit
(LU, ISLU, RT, etc.) being tested. When an individual unit is suspended a SINGLE CIRCUIT ABORT message is
created. The response to a manual
OP:LIT
input command will indicate if ALIT is currently suspended for a
particular unit.
There are two possible reports indicating the completion of an ALIT. One will indicate that all lines have been tested
in the scheduled time. The other report indicates that the test has stopped because the allotted time for the ALIT ran
out. The test will be terminated gracefully.
It is also possible to demand line insulation tests. They are called demand line insulation tests (DLIT). These tests
can be requested for one line or a range of lines, as well as a directory number.
NOTE:
When using directory number only one line can be requested. However, a range of lines may be requested
when using line equipment number.
3.4.3 SUBSCRIBER LINE INSTRUMENT MEASUREMENT (SLIM)
The subscriber line instrument measurement (SLIM) equipment is located in the modular metallic service unit
(MMSU) which is one of the SM service units. SLIM is used to test subscriber analog lines for voltage, resistance,
and capacitance. A Routine and Operator mode of operation is provided.
Routine:
This mode is used for automatic testing of analog lines. In this mode, a set of tests will run at a scheduled
time on a large number of analog lines. The tests, thresholds, and time schedules are defined via recent change
data. The parameters that have to be filled in can be found in the Recent Change Manual. The routine mode is
normally used to test large numbers of analog lines during times when machine traffic is at a minimum. Analog lines
that fail the test thresholds are stored on disk as line equipment numbers (LENs). At the end of the scheduled time,
these results are printed on the ROP.
The SLIM test status (suspended, done, in progress, scheduled or defined) and control (allow, inhibit, abort pokes)
can be viewed on the 162 [,1-4] page or using commands for that unit (
OP:TSESS; ALW:TSESS; INH:TSESS;
ABT:TSESS; DUMP:FILEA;
).
235-105-210
October 1999
Copyright © 1999
Page 4
Содержание 5ESS-2000
Страница 96: ...235 105 210 October 1999 Copyright 1999 Page 2 ...
Страница 184: ...235 105 210 October 1999 Copyright 1999 Page 3 ...
Страница 300: ...13 STOP YOU HAVE COMPLETED THIS PROCEDURE 235 105 210 October 1999 Copyright 1999 Page 55 ...
Страница 339: ...7 STOP YOU HAVE COMPLETED THIS PROCEDURE 235 105 210 October 1999 Copyright 1999 Page 13 ...
Страница 342: ...235 105 210 October 1999 Copyright 1999 Page 2 ...
Страница 359: ...235 105 210 October 1999 Copyright 1999 Page 5 ...
Страница 516: ...Figure 10 24 1 KS 23483 L13 Disk Drive Cable Connection Rear View 235 105 210 October 1999 Copyright 1999 Page 2 ...
Страница 517: ...Figure 10 24 2 KS 23483 L21 Disk Drive Cable Connection Rear View 235 105 210 October 1999 Copyright 1999 Page 3 ...
Страница 518: ...Figure 10 24 3 KS 23841 L15 Disk Drive Cable Connection Rear View 235 105 210 October 1999 Copyright 1999 Page 4 ...
Страница 523: ...Figure 10 24 6 Top View of DUP Showing Internal Cabling 235 105 210 October 1999 Copyright 1999 Page 9 ...
Страница 609: ...2 STOP YOU HAVE COMPLETED THIS PROCEDURE 235 105 210 October 1999 Copyright 1999 Page 12 ...
Страница 628: ...a SM inhibited Response OK 2 STOP YOU HAVE COMPLETED THIS PROCEDURE 235 105 210 October 1999 Copyright 1999 Page 8 ...
Страница 653: ...Response OK 2 STOP YOU HAVE COMPLETED THIS PROCEDURE 235 105 210 October 1999 Copyright 1999 Page 16 ...
Страница 676: ...235 105 210 October 1999 Copyright 1999 Page 9 ...
Страница 792: ...3 STOP YOU HAVE COMPLETED THIS PROCEDURE 235 105 210 October 1999 Copyright 1999 Page 9 ...
Страница 799: ...Figure 11 36 3 1 Cleaning Points 235 105 210 October 1999 Copyright 1999 Page 7 ...
Страница 801: ...235 105 210 October 1999 Copyright 1999 Page 9 ...
Страница 839: ...2 STOP YOU HAVE COMPLETED THIS PROCEDURE 235 105 210 October 1999 Copyright 1999 Page 16 ...
Страница 999: ...2 STOP YOU HAVE COMPLETED THIS PROCEDURE 235 105 210 October 1999 Copyright 1999 Page 13 ...
Страница 1008: ...Figure 11 55 1 CTSNS DIP Switch Settings 235 105 210 October 1999 Copyright 1999 Page 2 ...
Страница 1011: ...235 105 210 October 1999 Copyright 1999 Page 5 ...
Страница 1053: ...235 105 210 October 1999 Copyright 1999 Page 15 ...
Страница 1165: ...Procedure 14 14 RESERVED FOR FUTURE USE PROCEDURE 1 Reserved For future use 235 105 210 October 1999 Copyright 1999 Page 1 ...
Страница 1186: ...Procedure 14 17 RESERVED FOR FUTURE USE PROCEDURE 1 Reserved For future use 235 105 210 October 1999 Copyright 1999 Page 1 ...
Страница 1187: ...Procedure 14 18 RESERVED FOR FUTURE USE PROCEDURE 1 Reserved For future use 235 105 210 October 1999 Copyright 1999 Page 1 ...
Страница 1284: ...Figure 15 15 1 PARADYNE Paradyne Corporation 3810 Modem Diagnostic Control Panel 235 105 210 October 1999 Copyright 1999 Page 6 ...
Страница 1287: ...Figure 15 16 1 153A Adapter Connection Figure 15 16 2 AMATPS Block Diagram 235 105 210 October 1999 Copyright 1999 Page 3 ...
Страница 1289: ...Figure 15 17 2 AMATPS Data Link 235 105 210 October 1999 Copyright 1999 Page 2 ...
Страница 1290: ...Figure 15 17 3 Single Housing B25A Cable Assembly 235 105 210 October 1999 Copyright 1999 Page 3 ...
Страница 1292: ...235 105 210 October 1999 Copyright 1999 Page 5 ...
Страница 1294: ...Figure 15 17 8 201C to TN82 Data Set Cable Drawing 235 105 210 October 1999 Copyright 1999 Page 7 ...
Страница 1303: ...9 STOP YOU HAVE COMPLETED THIS PROCEDURE 235 105 210 October 1999 Copyright 1999 Page 2 ...
Страница 1324: ...11 Type and enter q 12 STOP YOU HAVE COMPLETED THIS PROCEDURE 235 105 210 October 1999 Copyright 1999 Page 2 ...
Страница 1342: ...Figure 15 40 1 SCANS II Dial Up Data Set Installation Diagram 235 105 210 October 1999 Copyright 1999 Page 2 ...
Страница 1344: ...Figure 15 40 4 59A1 Mounting Front in Slot J3 Figure 15 40 5 2048A Data Set Front 235 105 210 October 1999 Copyright 1999 Page 4 ...
Страница 1345: ...Figure 15 40 6 Berg Connector Terminations and Layout 235 105 210 October 1999 Copyright 1999 Page 5 ...
Страница 1346: ...Figure 15 40 7 B25A Cable 4 STOP YOU HAVE COMPLETED THIS PROCEDURE 235 105 210 October 1999 Copyright 1999 Page 6 ...
Страница 1360: ...Figure 15 47 2 Typical SCANS III Link Diagram 235 105 210 October 1999 Copyright 1999 Page 2 ...
Страница 1368: ...Response FA or OK appears 17 STOP YOU HAVE COMPLETED THIS PROCEDURE 235 105 210 October 1999 Copyright 1999 Page 2 ...
Страница 1372: ...235 105 210 October 1999 Copyright 1999 Page 2 ...
Страница 1374: ...235 105 210 October 1999 Copyright 1999 Page 4 ...
Страница 1376: ...Figure 15 55 6 201C to TN83 Data Set Cable Drawing 235 105 210 October 1999 Copyright 1999 Page 6 ...
Страница 1418: ...Figure 15 56 1 PARADYNE 3810 Modem Diagnostic Control Panel 235 105 210 October 1999 Copyright 1999 Page 4 ...
Страница 1421: ...Table 1 1 O M Checklist 235 105 210 October 1999 Copyright 1999 Page 3 ...