Chapter 5 - Parameter List
73
Keypad Display
Setting Range
Code
Description
LCD
7-Segment
LCD
7-Segment
Units
Factory
Default
Adj.
During
Run
Page
EXT-31
Multi-function Output
Terminal ‘Q2’ Define
Q2 define
31
-
FDT-2
Yes
EXT-32
Multi-function Output
Terminal ‘Q3’ Define
Q3 define
32
Same as Above
-
FDT-3
Yes
140
Frequency
0
Current
1
Voltage
2
DC link Vtg
3
EXT-34
LM (Load Meter) Output
Selection
LM mode
34
Torque
4
-
Current
Yes
140
EXT-35
LM Output Adjustment
LM adjust
35
10 to 200 [%]
1
100 [%]
Yes
140
Frequency
0
Current
1
Voltage
2
DC link Vtg
3
EXT-40
AM1 (Analog Meter 1)
Output Selection
AM1 mode
40
Torque
4
-
Frequency Yes
EXT-41
AM1 Output Adjustment
AM1 adjust
41
10 to 200 [%]
1
100 [%]
Yes
Frequency
0
Current
1
Voltage
2
DC link Vtg
3
EXT-42
AM2 (Analog Meter 2)
Output Selection
AM2 mode
42
Torque
4
-
DC link Vtg Yes
EXT-43
AM2 Output Adjustment
AM2 adjust
43
10 to 200 [%]
1
100 [%]
Yes
141
EXT-50
Speed Limit Level
Speed Limit
44
0 to 100 [%]
0.1
100 [%]
No
EXT-51
Speed Limit Bias
Speed Bias
45
0 to 200 [%]
0.1
100 [%]
No
EXT-52
Speed Limit Gain
Speed Gain
46
1 to 10
1
1
No
Reverse
0
EXT-53
Speed Limit Direction
Speed Dir
47
Forward
1
-
Forward
No
142
EXT-54
Zero Speed Detection
Level
ZSD Level
48
0 to 120 [Hz]
0.01
2 [Hz]
Yes
EXT-55
Zero Speed Detection
Bandwidth
ZSD Band
49
0 to 5 [Hz]
0.01
1 [Hz]
Yes
144
EXT-56
Torque Detection Level
TD Level
50
0 to 150 [%]
0.1
100 [%]
Yes
EXT-57
Torque Detection
Bandwidth
TD Band
51
0 to 10 [%]
0.1
5 [%]
Yes
144
EXT-99
Return Code
Not displayed
99
Not available
-
1
Yes
-
Morek IT OÜ, Rauna 24, 76506 Saue Harjumaa, Estonia. www.morek.eu Tel. +372 604 1423 Fax +372 604 1447 [email protected]