Chapter 4 – Quick start procedures
54
4.3 Operation using Keypad and Control Terminals
4.3.1
Frequency set by External Source and Run/Stop by Keypad
1.
Install a potentiometer on terminals V1, VR, 5G and connect wiring as shown below left.
When a ‘4 to 20mA’ current source is used as the frequency reference, use terminals I and 5G as shown below.
2.
Apply AC power.
3.
LCD:
Press
[
?
]
key to move DRV 03.
7-Seg:
Rotate encoder knob until ‘03’ is
displayed.
4.
LCD:
Press
[PROG]
key.
7-Seg:
Press
[PROG/ENT]
key.
5.
LCD:
Press
[
?
]
key one time.
7-Seg:
Rotate encoder knob and set at ‘0’.
6.
LCD:
Press
[ENT]
key.
7-Seg:
Press
[PROG/ENT]
key.
7.
Confirm that the DRV 04 is set at ‘V1’.
8.
Press
[SHIFT/ESC]
key.
Set the frequency by rotating the
potentiometer.
9.
LCD:
Press
[FWD]
or
[REV]
key.
7-Seg:
Press
[RUN]
key.
P1 P2
JOG
CM
P3 FX RX NC
CM BX
RST
I
VR VI
FM 5G
4 to 20mA signal
1
㏀
, 1/2 W
P1 P2
JOG
CM
P3 FX RX NC
CM BX
RST
I
VR VI
FM 5G
DRV 04
must be set at
V1
.
DRV 04
must be set at
I
.
DRV?T/K 0.0 A
00 STP 0.00Hz
The DRV LED is ON.
DRV? Drive mode
03 Fx/Rx-1
DRV? Drive mode
03 Fx/Rx-1
The PROG/ENT LED is turned ON.
DRV? Drive mode
03 Keypad
The PROG/ENT LED is turned ON.
DRV? Drive mode
03 Keypad
The PROG/ENT LED is turned OFF.
DRV? Freq mode
04 V1
The PROG/ENT LED is turned ON.
DRV?T/V 0.0 A
00 STP 60.00Hz
The FWD or REV LED starts blinking.
The RUN LED starts blinking.
To change the motor running
direction, change DRV 13 to ‘1’.
Morek IT OÜ, Rauna 24, 76506 Saue Harjumaa, Estonia. www.morek.eu Tel. +372 604 1423 Fax +372 604 1447 [email protected]