336
CN4093 Application Guide for N/OS 8.4
NPV Gateway
As
a
Node
Port
Virtualized
(NPV)
gateway,
the
CN4093
can
act
as
a
Fibre
Channel
collector,
connecting
numerous
Fibre
Channel
end
‐
point
devices
(known
as
nodes)
for
uplink
to
a
Fibre
Channel
full
fabric
switch,
performing
stateless
FC/FCoE
encapsulation
and
decapsulation.
For
more
details,
see
NPV Port Traffic Mapping
Within
each
VLAN
used
with
Fibre
Channel,
the
physical
ports
may
be
used
in
the
following
roles:
NPV
External
Interfaces
All
NPV
gateways
on
the
CN4093
must
connect
to
a
full
fabric
switch.
The
NPV
external
interface
map
specifies
which
Fibre
Channel
port
or
ports
(Omni
Ports
set
to
Fibre
Channel
mode)
are
used
for
this
purpose
within
each
Fibre
Channel
VLAN.
At
least
one
Fibre
Channel
port
is
required,
though
two
are
typically
used
in
order
to
provide
redundancy.
The
following
VLAN
configuration
command
is
used
to
define
or
remove
the
uplink:
Fibre
Channel
over
Ethernet
node
Traffic
from
Ethernet
ports
which
are
properly
configured
to
use
CEE
and
FCoE
(see
is
permitted
with
no
additional
configuration.
Ethernet
Traffic
on
regular
(non
‐
FCoE)
Ethernet
ports
will
be
blocked
on
Fibre
Channel
VLANs.
NPV Disruptive Load-Balancing
Every
server
connected
to
the
NPV
gateway
logs
into
an
upstream
FC
switch
through
a
NP
uplink.
If
multiple
NP
uplinks
are
available
in
a
NPV
VLAN,
the
logins
are
evenly
distributed
over
the
available
uplinks.
The
number
of
logins
per
uplink
can
go
out
of
balance
if
a
failed
NP
uplink
is
restored
or
a
new
uplink
is
brought
online.
The
NPV
gateway
does
not
automatically
move
Enodes
from
the
existing
to
new
uplinks
in
such
situations.
To
force
the
logins
to
be
evenly
distributed
among
all
available
uplinks
in
a
NPV
VLAN,
the
load
‐
balancing
CLI
is
available
under
the
VLAN
config.
Disruptive
load
‐
balancing
can
be
configured
through
two
available
options:
manual
‐
triggers
a
disruptive
load
‐
balance
among
the
logged
‐
in
nodes
in
the
current
NPV
VLAN.
The
CLI
for
this
option
is:
Note:
This
option
addresses
only
the
current
imbalance.
The
CLI
must
be
run
again
if
any
event
causes
uneven
distribution
in
the
future.
CN 4093(config-vlan)#
[no] npv traffic-map external-interface
<ports>
CN 4093(config-vlan)#
npv disruptive-load-balance
Содержание Flex System Fabric CN4093
Страница 27: ... Copyright Lenovo 2017 27 Part 1 Getting Started ...
Страница 28: ...28 CN4093 Application Guide for N OS 8 4 ...
Страница 58: ...58 CN4093 Application Guide for N OS 8 4 ...
Страница 72: ...72 CN4093 Application Guide for N OS 8 4 ...
Страница 85: ... Copyright Lenovo 2017 85 Part 2 Securing the Switch ...
Страница 86: ...86 CN4093 Application Guide for N OS 8 4 ...
Страница 98: ...98 CN4093 Application Guide for N OS 8 4 ...
Страница 112: ...112 CN4093 Application Guide for N OS 8 4 ...
Страница 136: ...136 CN4093 Application Guide for N OS 8 4 ...
Страница 156: ...156 CN4093 Application Guide for N OS 8 4 ...
Страница 192: ...192 CN4093 Application Guide for N OS 8 4 ...
Страница 228: ...228 CN4093 Application Guide for N OS 8 4 ...
Страница 229: ... Copyright Lenovo 2017 229 Part 4 Advanced Switching Features ...
Страница 230: ...230 CN4093 Application Guide for N OS 8 4 ...
Страница 298: ...298 CN4093 Application Guide for N OS 8 4 ...
Страница 382: ...382 CN4093 Application Guide for N OS 8 4 ...
Страница 392: ...392 CN4093 Application Guide for N OS 8 4 ...
Страница 416: ...416 CN4093 Application Guide for N OS 8 4 ...
Страница 452: ...452 CN4093 Application Guide for N OS 8 4 ...
Страница 466: ...466 CN4093 Application Guide for N OS 8 4 ...
Страница 496: ...496 CN4093 Application Guide for N OS 8 4 ...
Страница 508: ...508 CN4093 Application Guide for N OS 8 4 ...
Страница 510: ...510 CN4093 Application Guide for N OS 8 4 ...
Страница 514: ...514 CN4093 Application Guide for N OS 8 4 ...
Страница 538: ...538 CN4093 Application Guide for N OS 8 4 ...
Страница 539: ... Copyright Lenovo 2017 539 Part 7 Network Management ...
Страница 540: ...540 CN4093 Application Guide for N OS 8 4 ...
Страница 554: ...554 CN4093 Application Guide for N OS 8 4 ...
Страница 576: ...576 CN4093 Application Guide for N OS 8 4 ...
Страница 596: ...596 CN4093 Application Guide for N OS 8 4 ...
Страница 604: ...604 CN4093 Application Guide for N OS 8 4 ...
Страница 609: ... Copyright Lenovo 2017 609 Part 9 Appendices ...
Страница 610: ...610 CN4093 Application Guide for N OS 8 4 ...
Страница 626: ...626 CN4093 Application Guide for N OS 8 4 ...
Страница 633: ......
Страница 634: ...Part Number 00MY375 Printed in USA IP P N 00MY375 ...