User manual of EL8-EC***F AC Servo
279
2
Probe 1 trigger signal selection
0—EXT1 signal
1--Z signal
3
Reserved
-
4
Probe 1 rising edge trigger
0--Disable
1--Enable
5
Probe 1 falling edge trigger
0--Disable
1--Enable
6-7
Reserved
-
8
Probe 2 enable
0--Disable
1--Enable
9
Probe 2 mode
0--Single trigger mode
1--Continuous trigger mode
10
Probe 2 trigger signal selection
0—EXT2 signal
1--Z signal
11
Reserved
-
12
Probe 2 rising edge trigger
0--Disable
1--Enable
13
Probe 2 falling edge trigger
0--Disable
1--Enable
14-15
Reserved
-
6.17.4 Probe Status Word 60B9h
Bit
Definition
Details
0
Probe 1 enable
0--Disable
1--Enable
1
Probe 1 or Z-signal rising edge trigger
0-- not executed
1-- executed
2
Probe 1 or Z-signal falling edge trigger
0-- not executed
1-- executed
3-5
Reserved
-
6-7
Reserved
-
8
Probe 2 enable
0--Disable
1--Enable
9
Probe 2 or Z-signal rising edge trigger
0-- not executed
1-- executed
10
Probe 2 or Z-signal falling edge trigger
0-- not executed
1-- executed
11-13
Reserved
-
14-15
Reserved
-
6.17.6 Latch Position Register
Index
Details
60BAh
Probe 1
or Z-signal
rising edge latch position
60BBh
Probe 1
or Z-signal
falling edge latch position
60BCh
Probe 2
or Z-signal
rising edge latch position
60BDh
Probe 2
or Z-signal
falling edge latch position
Содержание EL8-EC Series