User manual of EL8-EC***F AC Servo
158
6091h-0
2
denominator
e
32
Access
RW
Mapping
RPDO
Mode
F
Range
1-21474
83647
Defaul
t
1
To set electronic gear ratio denominator
Index
6092h-0
1
Name
Number of pulses per
rotation
Unit
Comma
nd unit/r
Structur
e
VAR
Type
UInt
32
Access
RW
Mapping
RPDO
Mode
F
Range
1~2147
483647
Defaul
t
10000
If 6092h-01(Feed constant) is not equal to 608Fh(Position encoder resolution), then:
Electronic gear ratio = Encoder resolution / 6092h-01
If 6092h-01(Feed constant) is equal to 608Fh(Position encoder resolution), then:
Electronic gear ratio = 6091-01 / 6092h-01
4.3 Front Panel
Servo Drive front panel consists of 5 push buttons , a 8-segments display and 5 green
LED as warning indicators. Can be used for displaying of status, alarms, functions,
parameters setting and auxiliary functions.
Front panel
Buttons and functions
Label
Symbol
Function
Display
/
Consists of 5 push buttons , a 8-segments display and 5 green
LED as warning indicators
Mode
M
To switch between 3 modes:
1. Data monitoring mode : To monitor changes of motion data
values
2. Parameters setting mode : To set parameters
3. Auxiliary functions mode: To operate common functions, such
as trial run, alarm clearing
Enter
S
To enter or confirm
Up
▲
To switch between sub-menus / Increase
Down
▼
To switch between sub-menus / Decrease
Left
◄
To switch between values