User manual of EL8-EC***F AC Servo
159
4.4 Panel Display and Operation
4.4.1 Panel Operation
Display
rEAdy
for 1s
Initialization display
Data monitoring
mode
D35 SF
Parameter setting
Display monitoring data
Modify
parameter
Power on
S 0
S
D00 uE
D01 SP
◀
M
Select
needed
value
辅助功能模式
M
S
Parameter
value
0
r
0
Trial run
Vog -
S r U o n
p 400
Trial run
velocity
S
S
M
PA 0001
PA 0000
PA 0095
P A 0 0 0 0
P A 9 0 0 0
AF V o g
A F InI
A F r s t
Flow diagram of panel operation
(1)
rEAdY
will be displayed for about 1 second after driver is powered on. Then,
automatically enters data monitoring mode and displays initial data value. Otherwise,
alarm code will be displayed if error occurs.
(2) Press
M
key to switch between modes.
Data monitoring mode → Parameters setting mode → Auxiliary functions mode
Alarm code will be displayed regardless of any mode if alarm occurs. Press
M
to switch to
other modes.
(3) Press
or
to select the type of parameters in data monitoring mode. Press
S
to
confirm.
(4) Press
to select current segment in parameters settings mode. Press
or
to
increase/decrease the value of segment. Press
S
to confirm the modified value(s) and
save the parameters.