User manual of EL8-EC***F AC Servo
92
Pr2.37
Label
6
th
anti-resonant frequency
Mode
F
Range
50~4000
0
Unit
Hz
Default
4000
Index
2237h
Activation
Immediate
To set zero-valued eigenfrequency of 6
th
resonant notch filter. Pr2.37 corresponds to
machine-specific anti-resonant frequency.
Pr2.38
Label
6
th
anti-resonant Q value
Mode
F
Range
0~9900
Unit
Hz
Default
0
Index
2238h
Activation
Immediate
To set resonant Q value of 6
th
resonant notch filter
Pr2.48
Label
Adjustments mode
Mode
F
Range
0~1
Unit
-
Default
0
Index
2248h
Activation
Immediate
To turn on/off automatic adjustments
Set value
Description
【
0
】
Turn off automatic adjustments
1
Activate automatic adjustments, real time inertia measuring and
vibration suppression. Inertia measuring deactivated after
reaching 4 times in 5 minutes, triggering conditions: changes in
mechanical stiffness.
Pr2.50
Label
MFC type
Mode
PP
CS
P
Range
0~3
Unit
-
Default
0
Index
2250h
Activation
After restart
Set value
Description
【
0
】
Model following control
1
Zero tracking control
2
3 inertia (future upgrade)
3
Path following (future upgrade)