2.16.3 Common digital output
There are 3 digital outputs which are double-ended, having an isolated 24v power supply.
Double-ended output DO1-DO3
1
2
25
26
DO1+
DO1-
DO2+
DO2-
Driver interior
12~24Vdc
12~24Vdc
4
DO3+
DO3-
12~24Vdc
3
Flyback diode
required when
load is inductive
No flyback
diode required
for external load
NPN configuration DO1-DO3
DO1+
DO1-
12~24Vdc
Servo drive
Load
PNP configuration DO1-DO3
DO1+
DO1-
12~24Vdc
Servo drive
Load
Power supply is provided by user. Please be aware that reversed power supply
polarity might cause damage to the driver.