User manual of EL8-EC***F AC Servo
222
Related Objects
Basic object
PDO
Index+Sub-Index
Name
Data Type
Access
Unit
Notes
(RXPDO)
6040-00h
Control word
U16
RW
—
Required
60FF-00h
Target velocity
I32
RW
Uint
Required
6083-00h
Acceleration
I32
RW
Uint /S
Optional
(TXPDO)
6041-00h
Status word
U16
RO
—
Required
6064-00h
Position feedback
I32
RO
Uint
Optional
606C-00h
Velocity feedback
I32
RO
Uint /S
Optional
60F4-00h
Actual following error
I32
RO
Uint
Optional
6077-00h
Actual torque
I16
RO
0.1%
Optional
Extended object
Index+Sub-Index
Name
Data
Type
Access
Unit
603F-00h
Error code
U16
RO
—
6060-00h
Operation mode
I8
RW
—
6061-00h
Displayed operation mode
I8
RO
—
605A-00h
Quick stop option
I16
RW
—
6084-00h
Deceleration
U32
RW
Uint /S
6085-00h
Quick stop deceleration
U32
RW
Uint /S
Control Word and Status Word for Profile Velocity Mode
The bit6~4 of control words (6040h) associated with the control mode in PV mode are
invalid. The motion in PV mode can be triggered as long as the motion parameters (target
velocity (60FFh) ACC/DEC (6083h/6084h)) are given after the axis is enabled.
Table7. Bit15~12
、
10
、
8 of Status word (6041h) for Profile Velocity Mode
Bit
(Label)
Value
Details
8
(Quick stop)
0
Quick stop invalid
1
Quick stop valid
10
(Velocity reached)
0
Velocity not yet reached
1
Velocity reached
12
(Zero speed)
0
It's not zero speed. It's moving.
1
Zero speed or it's going to slow down to zero speed
*1)
*1) Zero speed of bit 12 is generally effective when deceleration stop and hardware limit