User manual of EL8-EC***F AC Servo
95
Pr3.14
Label
Sigmoid
acceleration/deceleration
settings
Mode
PV
CS
V
Range
0~1000
Unit
ms
Default
0
Index
2314h
Activation
Axis disable
To set sigmoid acceleration and deceleration turning point in accordance to Pr3.12 and Pr3.13.
Velocity
(RPM)
Time
Target
velocity
Vc
ta=Vc/1000 PA3.12 1ms
td=Vc/1000 PA3.13 1ms
ts=Pr3.14 1ms
Please set according to
ta/2>ts
、
td/2>ts
ts
ts
ts
ts
ta
td
Pr3.15
Label
Zero speed clamp function
selection
Mode
F
Range
0~3
Unit
-
Default
0
Index
2315h
Activation
Immediate
Set
value
Zero speed clamp function
0
Invalid: zero speed clamp deactivated
1
Velocity command is forced to 0 when the zero speed clamp (ZEROSPD) input
signal is valid.
2
Velocity command is forced to 0 when actual velocity is lower than Pr3.16.
3
Includes conditions from 1 and 2
Pr3.16
Label
Zero speed clamp level
Mode
PV
CSV
Range
10~2000
Unit
RPM
Default
30
Index
2316h
Activation
Immediate
Velocity command is forced to 0 when actual velocity is lower than Pr3.16 and after static time set
in Pr3.23