User manual of EL8-EC***F AC Servo
77
Pr0.31
Label
External encoder type
Mode
F
Range
0~3
Unit
-
Default
0
Index
2031h
Activation
Immediate
Set value
Description
【
0
】
ABZ encoder
1~3
Reserved for future upgrades
Pr0.32
Label
External encoder direction
Mode
F
Range
0~1
Unit
-
Default
0
Index
2032h
Activation
Immediate
Set value
Description
【
0
】
Default direction
1
Inversed direction
Pr0.33
Label
Excessive hybrid deviation
Mode
PP
H
M
CS
P
Range
0~1342
17728
Unit
Comma
nd unit
Default
16000
Index
2033h
Activation
After restart
To set the excessive hybrid deviation threshold value, please set accordingly. Use in full closed
loop control. Factory default: 16000. Er191 might occur if position deviation during hybrid control
exceeds 16000 pulse counts.
Pr0.34
Label
Clear hybrid control
deviation
Mode
PP
H
M
CS
P
Range
0~100
Unit
R
Default
0
Index
2034h
Activation
After restart
To set condition to clear position deviation under hybrid control mode (Full closed loop)
Set value
Description
【
0
】
OFF
1~100
Revolution count to clear hybrid control deviation
Pr0.35
Label
External encoder frequency
divider numerator
Mode
F
Range
0~2
23
Unit
-
Default
0
Index
2035h
Activation
After restart
When Pr0.35 = 0, numerator = resolution of encoder
Содержание EL8-EC Series
Страница 1: ...EL8 EC Series AC Servo Drive User Manual ...
Страница 299: ...User manual of EL8 EC F AC Servo 299 ...