User manual of EL8-EC***F AC Servo
166
8. d11Ai Analog input
_ 2 0
Analog input 1
(
Unit: 0.001V
)
D11 Ai
S
▲
▼
- 2 0
▲
▼
_ 2 0
Analog input 2
(
Unit: 0.001V
)
Analog input 3
(
Unit: 0.001V
)
3 analog inputs can be monitored through d11. Left most bar at the top: 1
st
analog input;
at the middle: 2
nd
analog input; at the bottom 3
rd
analog input. Points on 4
th
and 5
th
value
means negative value.
9. d12Er Alarm cause and historical record
Er 150
D12 Er
S
01 150
14 0E2
……Current error
……Historical record 1
(
Latest
)
……Historical record 14
(
Oldest
)
Press
▲▼
to check error historical
record up to 14 records.
Please refer to the alarm list table in chapter 8 for alarms that can be recorded.
10. d14rg Regenerative load factor d15oL Overload factor
Regenerative load factor
(
Er120 might occur, if the value increases indefinitely
)
5 0
D1 4rg
S
Load factor in
regenerative resistance
circuit [%]
Overload factor
(
Er100 might occur, if d increases indefinitely
Er101 might occur, if L increases indefinitely
)