Handbook OPTIFLEX 1300 C
27 OPTIFLEX
1300
C
1.4
Other important information
1.4.1
Process conditions
Flange temperature
Process pressure
Observe process connection operational limits!
Risk of injury and damage to device!
The operating pressure allowed depends on the temperature at the process connection. The mechanical
properties of the process connection are influenced by temperature.
For further information, refer to relevant national standards. For example
European
EN 1092-1 Flanges and their joints. Circular flanges for pipes, valves, fittings and accessories, PN
designated. Steel flanges
US
ASME B16.5a Addenda to ASME B16.5 Pipe flanges and flanged fittings NPS ½ through NPS 24
1.4.2
Electrostatic discharge
General notes
This may occur in some solid applications.
Device ESD protection
OPTIFLEX 1300 C non-Ex and Ex gauge electronics are shielded up to 16KV against electrostatic
discharge (ESD).
Electrostatic discharge!
Risk of measurement error and/or damage to housing electronics!