3.3 CHECKING LAMP
3.3.1 Checking Function of Warning Lamps
Touching any control levers unintentionally may cause unexpected movement of the machine. Set the
pilot control shut-off lever to the "LOCKED" position before standing up or moving.
Before starting the engine, check the operation of the warning and display lamps according to the
following procedures.
For the description for each lamp, see "MONITOR PANEL" in Chapter 2.
1. Make sure the safety lever is in the
"LOCKED" position.
2. Make sure all control levers are in the
"NEUTRAL" position.
3. Insert the starter key into the starter switch
and turn it to each of the "HEAT", "ON" or
"START" position. If each warning lamp
operates as shown in the table below, it
works properly at each position.
4. If any warning or display lamp does not
operate properly, the engine or electrical
circuit components may be broken. Stop
using the machine and immediately contact
our authorized dealer/distributor for repair.
RED: Warning Lamp
YELLOW: Indication Lamp
1
5
3
2
4
Starter key
Operation
Lamp
OFF
→
HEAT
Preheat
OFF
→
ON
Before start
START
→
ON
Just after start
1 Engine oil pressure lamp
Unlit
Lit
Unlit
2 Battery charge lamp
Unlit
Lit
Unlit
3
Engine coolant temperature
lamp
Unlit
Unlit
Unlit
4 Fuel level lamp
Unlit
Unlit
Unlit
5
Travel in HIGH (2nd) speed
lamp
Unlit
Unlit
Unlit
Be sure to check that the warning and display lamps operate properly before operation.
[
3. MACHINE OPERATION
]
3-
10
Copyright©2019 Kobelco Construction Machinery Co.,Ltd. All rights reserved. [S2PS00017ZE08] [1226CsCshWbYs]