ASSEMBLY INSTRUCTIONS
H-LINE
New generation SEH
50/18, 50/23 & 63/30
ZMA015
GB 2020-09-01
Страница 1: ...ASSEMBLY INSTRUCTIONS H LINE New generation SEH 50 18 50 23 63 30 ZMA015GB 2020 09 01...
Страница 2: ......
Страница 3: ...correct use or lack of maintenance will not be covered by the warranty CE mark A CE mark is located on the transmission side of the elevator head and is proof that the machine has been manufactured in...
Страница 4: ......
Страница 5: ...veyor equipment for a long time Machine overview 6 Safety information 7 General safety information 7 Electrical safety 8 Safety decals 9 Before assembly 11 Connection of the machine 13 Location of inl...
Страница 6: ...oot 1 Clean out hatch 2 Inlet opening 3 Cover plate inlet hopper 4 Bucket belt 5 Elevator leg 6 Service door 7 Parts Pos Leg spacer plate 8 Back stop with guard 9 Elevator head 10 Elevator hood 11 Gea...
Страница 7: ...and interpreted as follows WARNING Disregarding instructions given in warnings can cause serious personal injury or death IMPORTANT Ignoring the instructions given in important texts may cause damage...
Страница 8: ...veyor equipment and or other equipment It can also cause malfunctions or a reduction in capacity WARNING All electrical equipment is to be connected by a qualified electrician See separate connecting...
Страница 9: ...d WARNING The mandatory instruction forbiddance or warning given on all safety decals must be considered or serious injury or death may follow Skandia Elevator machines have the following safety decal...
Страница 10: ...10 SKANDIA ELEVATOR SEH 50 18 50 23 63 30 DEK3060 Warning for bucket belt DEK3040 Warning for chain drive DEK3070 Warning for rotating conveyor drive shaft DEK3080 Warning for rotating elevator drive...
Страница 11: ...raise it if necessary NB Position the elevator boot so that the clean out hatches on all sides of the boot A are accessible and so that the planned connections can be made The elevator boot is prepar...
Страница 12: ...12 SKANDIA ELEVATOR SEH 50 18 50 23 63 30 IMPORTANT Fit the elevator vertically within the specified tolerances X and Y are vertical references 15 mm 15 mm 15 mm 15 mm 90 0 5 90 0 5 180 0 5 X Y...
Страница 13: ...y light material and slow running material must always be fed on the descending leg side Use only recommended inlet outlet and connecting components Ensure the ducting is dimensioned sufficiently and...
Страница 14: ...from the machines outlet hopper to the cover plate on the inlet hopper B of the elevator A conveyor can also be connected through a special outlet connection F directly to a connection hopper D Conne...
Страница 15: ...n the slatted pulleys WARNING All electrical equipment is to be connected by a qualified electrician See separate connecting directions for electronics Fit the belt alignment switch in the prepared lo...
Страница 16: ...ort frame read more in the Elevator head section in the following information NB The bracing requirements above are a basic condition for the strength of the elevator and must be followed If there is...
Страница 17: ...gs with explosion relief panels directly against the elevator boot and the others with a maximum of 6 metres spacing Fit the dust curtain with explosion relief panel in the head Use only explosion rel...
Страница 18: ...basic condition for the strength of the elevator and must be followed If there is a risk of gusts of wind stronger than 42 m s the distance between each horizontal bracing must be reduced in relation...
Страница 19: ...rst time Ensure that the bucket belt runs in the correct direction before refitting the back stop The damage that can be caused to the back stop geared motor by an incorrectly connected geared motor i...
Страница 20: ...as been assembled and restretched 1 Remove the service doors on both sides of the elevator leg 2 Fit the sleeve profile A on the back of the elevator leg 3 Pull the bucket belt in place over the slatt...
Страница 21: ...10 Cut the belt ends 10 mm outside the splice bars and remove the belt tensioner profiles 11 Mount the buckets as described below under Buckets 12 Once the buckets have been mounted tension the bucket...
Страница 22: ...turn Repeat turn after turn until all the buckets are mounted IMPORTANT Fit the washers as illustrated and tighten the nuts hard enough so that the screw heads align exactly with the surface of the b...
Страница 23: ...t runs askew then it must be centred Example If the bucket belt runs to the right of the drive wheel in the elevator head loosen not fully the bolts A 4 pcs and B 6 pcs on the right hand side plate Ra...
Страница 24: ...24 SKANDIA ELEVATOR SEH 50 18 50 23 63 30 Adjusting the splash guard Adjusting the splash guard 10 mm A...
Страница 25: ...25 SKANDIA ELEVATOR SEH 50 18 50 23 63 30 Elevator hood Lift the parts of the hood into place Alt A or slide them into place Alt B fit and secure them Alt B Alt A1 Alt A2 M10x35...
Страница 26: ...or is engaged during operation All electrical equipment is to be connected by a qualified electrician See separate connecting directions for electronics The speed monitor stops the elevator if the buc...
Страница 27: ...en assembling outdoors seal all the bolts flanges and folds with silicone Inlet Prepare for and fit the inlet hoppers A B C or connection hopper D according to the chapter Before connection and Connec...
Страница 28: ...SKANDIA ELEVATOR AB KEDUMSV GEN 14 ARENTORP S 534 94 VARA SWEDEN PHONE 46 0 512 79 70 00 FAX 46 0 512 134 00 INFO SKANDIAELEVATOR COM WWW SKANDIAELEVATOR COM...