HOW TO CHECK
1. Start the engine, and set the engine throttle
lever to the middle speed position.
2. See the right table for reference.
(1) Temperature Adjustment Switch: C
(Lowest)
Door: Closed
Window: Closed
(2) Fan Speed Selector Switch: 3 (High)
(3) Air Conditioner Switch: ON
3. Determine the refrigerant volume based on
the following checks by looking through the
sight glass (inspection window) on the
receiver dryer.
(Figure (A): The refrigerant volume is proper.
(Figure (B): The refrigerant is over charged.
This will make both high and low pressure
rise and exert a bad influence on the
pressure switch operation and the air
conditioning system.
(Figure (C): The refrigerant is insufficient.
Contact our authorized dealer/distributor for
recharge of the refrigerant.
A Proper
B Overcharged
After the air conditioner is turned ON, little
bubbles appear. The refrigerant becomes
transparent, then turns a light milky white.
After the air conditioner is turned ON, no
bubbles appear.
After the air conditioner is turned ON,
bubbles appear continuously.
Bubbles......... Refrigerant gas is mixed with
refrigerant fluid.
No Bubbles....Whole refrigerant becomes fluid and
transparent.
Cloudy........... Refrigerant is separated from oil.
The fluid becomes a light milky white.
Refrigerant volume
Description
C Insufficient
•Operate the air conditioner at least once every week for several minutes to rotate the compressor
regardless of the season.
•If an oil stain is found around a pipe joint, it is a sign of gas leakage. Contact our authorized
dealer/distributor for inspection.
•Follow the following regulations to conserve global environment.
1. Do not release the refrigerant which is sealed in this unit to the atmosphere.
2. Extract the sealed refrigerant from unit when disposing this unit.
[
8. OPTIONAL EQUIPMENT
]
8-
22
Copyright©2019 Kobelco Construction Machinery Co.,Ltd. All rights reserved. [S2PS00017ZE08] [1226CsCshWbYs]
Содержание SK55SRX-6
Страница 2: ...Copyright 2019 Kobelco Construction Machinery Co Ltd All rights reserved S2PS00017ZE08 1226CsCshWbYs...
Страница 10: ...CONTENTS 8 Copyright 2019 Kobelco Construction Machinery Co Ltd All rights reserved S2PS00017ZE08 1226CsCshWbYs...
Страница 142: ...4 MAINTENANCE 4 2 Copyright 2019 Kobelco Construction Machinery Co Ltd All rights reserved S2PS00017ZE08 1226CsCshWbYs...