50
PLZ-4WH
ABC Preset Memory
Recalling ABC preset memory entries
There are two methods of recalling the preset memory, “SAFETY” and “DIRECT.”
SAFETY
You can recall a memory entry after first checking its contents on the display.
DIRECT
The settings of the setup memory entry are applied immediately.
The factory default setting is “SAFETY.”
You can set the preset memory recall method (“SAFETY” or “DIRECT”) from the menu by
selecting “1. Setup” > “3. Memory.”
■
Memory recall method (SAFETY)
1
Configure the proper operation mode and range settings for the preset
memory entry that you want to recall.
2
Press the key that corresponds to the preset memory entry (A, B, or C)
that you want to recall.
The selected key lights.
The settings stored in the specified preset memory are displayed. You can recall a
different preset memory entry by pressing another preset memory key (A, B, or C).
3
Check the contents of the preset memory entry, and press ENTER.
The selected key lights. The settings that correspond to the selected memory entry
are recalled and applied. If you change the settings, the key light turns off.
■
Memory recall method (DIRECT)
1
Configure the proper operation mode and range settings for the preset
memory entry that you want to recall.
2
Press the key that corresponds to the preset memory entry (A, B, or C)
that you want to recall.
The selected key lights. The settings that correspond to the selected memory entry
are recalled and applied. If you change the settings, the key light turns off.
See
Memo
You can cancel by
pressing PREV
(SHIFT+
).
0.0000
A
0.00
V
0.00
W
CC
8.0000
A
2.0000
A
SET
RECALL
Setting saved to the
preset memory.
H 8.25A 650V
Содержание PLZ1004WH
Страница 13: ...Installation and Preparation This chapter describes how to unpack and prepare this product before you use it 1 ...
Страница 28: ...28 PLZ 4WH Remote Sensing ...
Страница 29: ...Basic Functions This chapter explains the operations for each operation mode and other basic functions 2 ...
Страница 47: ...Advanced Operations This chapter explains ABC preset memory setup memory protection functions and the menu 3 ...
Страница 61: ...Sequences This chapter explains the sequence function Sequences 4 ...
Страница 83: ...External Control and Parallel Operation This chapter explains external control and Parallel Operation 5 ...
Страница 115: ...Maintenance This chapter describes the maintenance procedures including cleaning inspection and calibration 7 ...
Страница 127: ...8 Specifications This chapter contains the specifications and gives the dimensions of the PLZ 4WH ...
Страница 137: ...Appendix A Operating Area B Sequence Program Creation Table C Options ...