PLZ-4WH
55
Protection Functions
3
Advance
d
Oper
ati
ons
1
Make sure that the load is off.
If the LOAD LED is lit, press LOAD to turn the load off.
2
Press OPP/OCP until OPP is highlighted on the display.
The OPP/OCP key lights. Pressing OPP/OCP switches between OCP and OPP.
3
Turn the rotary knob to set the overpower-protection-activation value.
Details about undervoltage protection (UVP)
You can set the value at which UVP is activated. You can disable UVP by setting the value to
OFF.
If the auto load-off timer is on, when UVP is activated, the time from load on to load off is
indicated in a popup window that appears.
■
Setting the undervoltage-protection-activation value
1
Press UVP (SHIFT+OPP/OCP).
The UVP key lights.
2
Turn the rotary knob to set the undervoltage-protection-activation value.
If you set the value to OFF, undervoltage protection is disabled.
Details about reverse-connection protection (REV)
When a reverse voltage is detected and the load is turned off, turn off the DUT immediately.
If you are using the remote sensing function and the sensing wires are connected in reverse,
a reverse voltage will not be detected because no current will flow even when the load is
turned on. Because there is no threat of damage or injury, no alarm occurs.
Clearing alarms
You can press ENTER when an alarm is activated to clear the alarm. However, the alarm will
be activated again if its cause has not been eliminated.
When alarm input is being detected, release the alarm of the PLZ-4WH after you release the
alarm of the device connected to external control.
See
See
Содержание PLZ1004WH
Страница 13: ...Installation and Preparation This chapter describes how to unpack and prepare this product before you use it 1 ...
Страница 28: ...28 PLZ 4WH Remote Sensing ...
Страница 29: ...Basic Functions This chapter explains the operations for each operation mode and other basic functions 2 ...
Страница 47: ...Advanced Operations This chapter explains ABC preset memory setup memory protection functions and the menu 3 ...
Страница 61: ...Sequences This chapter explains the sequence function Sequences 4 ...
Страница 83: ...External Control and Parallel Operation This chapter explains external control and Parallel Operation 5 ...
Страница 115: ...Maintenance This chapter describes the maintenance procedures including cleaning inspection and calibration 7 ...
Страница 127: ...8 Specifications This chapter contains the specifications and gives the dimensions of the PLZ 4WH ...
Страница 137: ...Appendix A Operating Area B Sequence Program Creation Table C Options ...