PLZ-4WH
59
Menu
3
Advance
d
Oper
ati
ons
List of menu items
(the factory default settings are underlined)
Item 1
Item 2
Item 3
Settings
Description
1.Setup
1.Function
Soft Start
1 ms, 2 ms, 5 ms, 10 ms, 20 ms,
50 ms, 100 ms, 200 ms
Soft start time
Count Time
OFF: Not displayed, ON: Displayed
Elapsed time display
Key Lock
SET-KEY: Most of the keys are locked.
ALL-KEY: All the keys are locked.
Key lock setting
2.Protect Action
OCP
LOAD OFF: The load is turned off.
LIMIT: The current is limited.
Action to be performed when OCP
is activated
OPP
LOAD OFF: The load is turned off.
LIMIT: The current is limited.
Action to be performed when OPP
is activated
3.Memory
Recall
DIRECT
SAFETY
Method for recalling the preset
memory
4.Cut Off
Time
OFF
0:00:01 to 999:59:59
(Hour:minute:second)
Auto load-off timer
Press
and
to move the
cursor between the hour, minute,
and second positions.
5.Response
CC/CR
1/1, 1/2, 1/5, 1/10
CC/CR mode response speed
CV
100, 10, 1, 1/10, 1/100
CV mode response speed
2.Configuration
1
1
The Configuration conditions, are enabled after the power switch is turned off and then on again.
1.Master/Slave
Operation
MASTER, SLAVE
Master-Slave control setting
Parallel
2
2
This is enabled when Operation is set to Master on the 1.Master/Slave screen.
-
, 2, 3, 4, 5
Number of electronic loads
operating in parallel
Booster
3
3
This is enabled when a PLZ1004WH is being used as the master unit and Operation is set to Master on the 1.Master/Slave screen.
-
, 1, 2, 3, 4
Number of boosters that are
connected
2.Power On
Load On
OFF: The load is off when the power is
turned on.
ON: The load is on when the power is
turned on.
State of the load when the power
switch is turned on
Key Lock
OFF: Keys are not locked.
ON: Keys are locked.
Key lock
3.Interface
Control
GPIB, RS232C, USB
Interface setting
GPIB
Address
1 to 30 (1)
GPIB address
RS232C Baudrate
2400bps, 4800bps, 9600bps, 19200bps
Baud rate
Data
4
,
Stop
4
Information about the PLZ-4WH. It cannot be changed.
8,
1/2
Data length (fixed at 8 bits) and the
stop bit
Parity
NONE
Parity (fixed at NONE)
Ack
OFF, ON
Acknowledgment
USB
VID
0x0B3E
Vendor ID
PID
0x1021
(
PLZ164WH
)
0x1022
(
PLZ334WH
)
0x1023
(
PLZ1004WH
)
Product ID
S/N
AB123456 (example)
Serial number
4.External
Control
OFF: Disabled, V: Control through
external voltage
R: Control through external resistance
(proportional)
Rinv: Control through external
resistance (inverted)
External control for the CC, CR,
and CP modes
Control CV
OFF: Disabled, ON: Enabled
External control for CV mode
LoadOn IN
LOW: Turned on by a low level
HIGH: Turned on by a high level
External control logic setting for
turning the load on and off
3.Calibration
1.CC(Low)
Calibration of the PLZ-4WH.
For details, see "Calibration" on page 118.
2.CC(Mid)
3.CC(High)
4.CV 65V
5.CV 650V
4.Model Info
(MODEL)
PLZxxxWH
Model name
VERSION SUB
x.xx
Firmware version
VERSION MAIN
x.xx
ROM version
Содержание PLZ1004WH
Страница 13: ...Installation and Preparation This chapter describes how to unpack and prepare this product before you use it 1 ...
Страница 28: ...28 PLZ 4WH Remote Sensing ...
Страница 29: ...Basic Functions This chapter explains the operations for each operation mode and other basic functions 2 ...
Страница 47: ...Advanced Operations This chapter explains ABC preset memory setup memory protection functions and the menu 3 ...
Страница 61: ...Sequences This chapter explains the sequence function Sequences 4 ...
Страница 83: ...External Control and Parallel Operation This chapter explains external control and Parallel Operation 5 ...
Страница 115: ...Maintenance This chapter describes the maintenance procedures including cleaning inspection and calibration 7 ...
Страница 127: ...8 Specifications This chapter contains the specifications and gives the dimensions of the PLZ 4WH ...
Страница 137: ...Appendix A Operating Area B Sequence Program Creation Table C Options ...