PLZ-4WH
49
3
Ad
vanced Operat
ions
ABC Preset Memory
You can save preset memory entries to A, B, or C. In A, B, and C, you can save fundamental
settings for each range of each operation mode. You can save and load preset memory
entries regardless of whether the load is on or off.
The protection-function-activation values are not saved. If the settings that you recall exceed
the protection-function-activation values, an alarm will occur.
In CC+CV mode, memory entries for CC mode and CV mode are used.
In CR+CV mode, memory entries for CR mode and CV mode are used.
Saving settings to ABC preset memory
For each range of each operation mode, you can save different settings to keys A, B, and C.
You can save the settings even when the load is on.
1
In the operation mode that you want to create a memory entry for, set the
range and values.
2
Press ABC (SHIFT+ENTER).
The A, B, and C keys start blinking.
3
Of A, B, and C, press the key that you want to save the settings to.
The key that you press lights, and the settings are saved to the key that you selected.
If you change the settings, the key light turns off.
Operation Mode
Fundamental Settings
CC mode
Current
CR mode
Conductance (resistance)
CP mode
Power
CV mode
Voltage
CC+CV mode
Current and voltage
CR+CV mode
Conductance (resistance) and voltage
Preset memory C
Preset memory B
CC mode
H range
M range
L range
CR mode
H range
M range
L range
CP mode
H range
M range
L range
CV mode
Current
Conductance
Power
Voltage
H range
L range
Preset memory A
CC mode
H range
M range
L range
CR mode
H range
M range
L range
CP mode
H range
M range
L range
CV mode
H range
L range
Preset memory A
For example, when you save to preset
memory A in CC+CV mode
(current: M range, voltage: L range):
Saved here
Содержание PLZ1004WH
Страница 13: ...Installation and Preparation This chapter describes how to unpack and prepare this product before you use it 1 ...
Страница 28: ...28 PLZ 4WH Remote Sensing ...
Страница 29: ...Basic Functions This chapter explains the operations for each operation mode and other basic functions 2 ...
Страница 47: ...Advanced Operations This chapter explains ABC preset memory setup memory protection functions and the menu 3 ...
Страница 61: ...Sequences This chapter explains the sequence function Sequences 4 ...
Страница 83: ...External Control and Parallel Operation This chapter explains external control and Parallel Operation 5 ...
Страница 115: ...Maintenance This chapter describes the maintenance procedures including cleaning inspection and calibration 7 ...
Страница 127: ...8 Specifications This chapter contains the specifications and gives the dimensions of the PLZ 4WH ...
Страница 137: ...Appendix A Operating Area B Sequence Program Creation Table C Options ...