Editing Steps in a Fast Sequence
4
Sequenc
es
Increasing the magnification in the step setting monitor screen
You can increase the magnification that the steps are monitored at.
Press
to move the cursor to the magnification, and use the rotary knob to change the
magnification. There are eight magnifications, from M1 to M8. The numbers indicate the
number of steps that are displayed on a single screen. M1 is the maximum magnification.
When you move the cursor to the step number by pressing
and then change the step
using the rotary knob, the waveform moves so that the selected step is in the center of the
rectangular monitor area.
When the magnification is set to M1, you can use the rotary knob to move one step at a time
and monitor the steps in detail. In the same way, when the magnification is M2, you can move
by two steps at a time; when the magnification is M3, you can move by three steps at a time;
and when the magnification is M8, you can move by eight steps at a time.
You can monitor all the steps up to the specified last step.
Press PREV (SHIFT+ ) to return to the previous screen.
FILL function
You can use the FILL function to automatically set the currents of a group of steps by setting
the currents of the step on each end of the group.
In the monitor screen, press INS (SHIFT+
) to display the FILL screen.
Press
or
to move the cursor to DATA1, and use the rotary knob to set the current of the
first step. In the same way, set DATA2 (the current of the last step), START (the step number
of the first step), and STOP (the step number of the last step).
After you have finished making the settings, press ENTER to return to the monitor screen.
In the example in the figure below, the same waveform is repeated twice.
First, set the first step to 16 and the current to 0.162 A, and set the last step to 100 and
the current to 1.164 A. Then, set the first step to 101 and the current to 0.164 A, and set
the last step to 200 and the current to 1.164 A.
See
See
Item
Setting
Description
DATA1
0 to 100 % of the range
The current of the first step
DATA2
0 to 100 % of the range
The current of the last step
START
1 to 1024
The step number of the first step
STOP
1 to 1024
1
1
You can set the number of the last step to any value up to 1024, but the last step that can be monitored
is determined by the value that you set for RPTSTEP.
The step number of the last step
10.00
A
STEP:0014
M1
DATA1 : 0.1620
A
DATA2 : 3.1620A
START : 0016
STOP : 1024
ENTER
FILL
Memo
You can set the number of
the last step to any value
up to 1024, but the last
step that can be
monitored is determined
by the value that you set
for RPTSTEP when you
edited the program.
Current
3.162 A
0.162 A
Step
16
100 101
200
10.00
A
STEP:0014
M1
DATA1: 0.1620
A
DATA2: 3.1620
A
START: 0016
STOP :
ENTER
FILL
0100
Steps 16 to 100
10.00
A
STEP:0014
M1
DATA1: 0.1620
A
DATA2: 3.1620
A
START: 0101
STOP :
ENTER
FILL
0200
Steps 101 to 200
(DATA2)
(DATA1)
(START)
(STOP) (START) (STOP)
Содержание PLZ1004WH
Страница 13: ...Installation and Preparation This chapter describes how to unpack and prepare this product before you use it 1 ...
Страница 28: ...28 PLZ 4WH Remote Sensing ...
Страница 29: ...Basic Functions This chapter explains the operations for each operation mode and other basic functions 2 ...
Страница 47: ...Advanced Operations This chapter explains ABC preset memory setup memory protection functions and the menu 3 ...
Страница 61: ...Sequences This chapter explains the sequence function Sequences 4 ...
Страница 83: ...External Control and Parallel Operation This chapter explains external control and Parallel Operation 5 ...
Страница 115: ...Maintenance This chapter describes the maintenance procedures including cleaning inspection and calibration 7 ...
Страница 127: ...8 Specifications This chapter contains the specifications and gives the dimensions of the PLZ 4WH ...
Страница 137: ...Appendix A Operating Area B Sequence Program Creation Table C Options ...