5
Ext
e
rn
al
Cont
rol
an
d Par
a
llel
Oper
at
ion
Making Sure That the Input Current Changes Proportionally to External Changes
By properly adjusting the OFS (to adjust the current offset) and FSC (to adjust the maximum
current) variable resistors on the rear panel, you will be able to control the input current
proportionally to the external voltage or resistance. The adjustments are valid for the
specified range. If you change the range, readjust the variable resistors.
A load current actually flows during the adjustment, so connect the power supply that you
want to test.
Making sure that the input current changes proportionally to
external voltage changes
During CV mode adjustment, use the CV variable resistors (the upper row) when you are
using pins 5 and 6 of the EXT CONTROL connector, and use the CC, CR, CV, and CP
variable resistors (the lower row) when you are using pins 1 and 3 of the EXT CONTROL
connector. In all modes other than CV mode, use the CC, CR, CV, and CP variable resistors
(the lower row).
1
Turn the load on.
2
Set the external voltage to 0 V.
3
Turn OFS until the measured current on the display is 0 A.
4
Set the external voltage to 10 V.
5
Turn FSC until the measured current on the display is 100 % of the
selected range.
6
Turn the load off.
This completes the adjustment procedure.
Making sure that the input current changes proportionally to
external resistance changes
Use the CC, CR, CV, and CP variable resistors (the lower row).
1
Turn the load on.
2
If you are performing proportional control, set the external resistance to
0
Ω
. If you are performing inverse control, set the external resistance to
10 k
Ω
.
3
Turn OFS until the measured current on the display is 0 A.
4
If you are performing proportional control, set the external resistance to
10 k
Ω
. If you are performing inverse control, set the external resistance
to 0
Ω
.
5
Turn FSC until the measured current on the display is 100 % of the
selected range.
6
Turn the load off.
This completes the adjustment procedure.
Adjustments during external control
using pins 1 and 3 of the EXT CONT
connector
Adjustments during external control using
pins 5 and 6 of the EXT CONT connector
Содержание PLZ1004WH
Страница 13: ...Installation and Preparation This chapter describes how to unpack and prepare this product before you use it 1 ...
Страница 28: ...28 PLZ 4WH Remote Sensing ...
Страница 29: ...Basic Functions This chapter explains the operations for each operation mode and other basic functions 2 ...
Страница 47: ...Advanced Operations This chapter explains ABC preset memory setup memory protection functions and the menu 3 ...
Страница 61: ...Sequences This chapter explains the sequence function Sequences 4 ...
Страница 83: ...External Control and Parallel Operation This chapter explains external control and Parallel Operation 5 ...
Страница 115: ...Maintenance This chapter describes the maintenance procedures including cleaning inspection and calibration 7 ...
Страница 127: ...8 Specifications This chapter contains the specifications and gives the dimensions of the PLZ 4WH ...
Страница 137: ...Appendix A Operating Area B Sequence Program Creation Table C Options ...