Operating Area
App.
■
Operation on segment GH
If the voltage of the constant-voltage power supply is set to V3 and the power of the PLZ-
4WH is increased (P
1
→
P
2
→
P
B
), thereby increasing the input current (load current), the
operating point moves along segment GH. Point G is the maximum power in the range being
used.
Point B
LOAD OFF
The load is turned off (no current flows).
The PLZ-4WH stops operating as a load.
LIMIT
The PLZ-4WH switches out of constant power (CP) mode.
Overcurrent protection (OCP) continues, and the PLZ-4WH
operates as a constant-current load.