Controlling the Current Range Externally
You can use an external control signal to control the current range. You can use the range
status output to monitor the present state of the range.
You cannot control the voltage range.
Set the current range on the panel to the H range.
The current range cannot be changed when the load is turned on. The control signal input
received while the load is turned on is ignored.
Input for switching the range externally
Use pins 8 (RANGE CONT 1) and 9 (RANGE
CONT 0) of the EXT CONT connector (use pin
12 as the common).
The signal is 2 bit.
The control terminals are pulled up to the
internal circuit’s +5 V level by a resistor that is
approximately 10 k
Ω
. The maximum allowable
voltage is 5 V. The logic threshold levels are
CMOS.
Range status output
Use pins 14 (RANGE STATUS 1) and
15 (RANGE STATUS 0) of the EXT
CONT connector (pin 17 is common).
The signal is 2 bit.
Current Range
Control Input
1
Status Output
2
PLZ
164WH
PLZ
334WH
PLZ
1004WH
RANGE
CONT 0
RANGE
CONT 1
RANGE
STATUS 0
RANGE
STATUS 1
H
8.25 A
16.5 A
50 A
HIGH
HIGH
OFF
OFF
M
0.825 A
1.65 A
5 A
HIGH
LOW
OFF
ON
L
82.5 mA
165 mA
500 mA
LOW
HIGH
ON
OFF
1
HIGH: 5 V, LOW: 0 V
2
OFF: OPEN, ON: SHORT
+5 V
Approx. 10 kΩ
A COM
EXT CONT
12
8, 9
EXT CONT
Photocoupler (P.C)
17
14, 15
Maximum applied voltage: 30 V
Maximum current:
8 mA
Содержание PLZ1004WH
Страница 13: ...Installation and Preparation This chapter describes how to unpack and prepare this product before you use it 1 ...
Страница 28: ...28 PLZ 4WH Remote Sensing ...
Страница 29: ...Basic Functions This chapter explains the operations for each operation mode and other basic functions 2 ...
Страница 47: ...Advanced Operations This chapter explains ABC preset memory setup memory protection functions and the menu 3 ...
Страница 61: ...Sequences This chapter explains the sequence function Sequences 4 ...
Страница 83: ...External Control and Parallel Operation This chapter explains external control and Parallel Operation 5 ...
Страница 115: ...Maintenance This chapter describes the maintenance procedures including cleaning inspection and calibration 7 ...
Страница 127: ...8 Specifications This chapter contains the specifications and gives the dimensions of the PLZ 4WH ...
Страница 137: ...Appendix A Operating Area B Sequence Program Creation Table C Options ...