5
Ext
e
rn
al
Cont
rol
an
d Par
a
llel
Oper
at
ion
Using a Trigger Signal to Control the PLZ-4WH
The application of a trigger signal during sequence execution unpauses the PLZ-4WH. Use a
trigger signal when you want to synchronize the PLZ-4WH with an external device.
Trigger signal input
Apply a voltage signal with a maximum allowable voltage of 5 V and a pulse width of 10 µs or
more across pins 11 and 12 of the EXT CONT connector.
The trigger signal is output on the rising edge of the pulse signal applied to the trigger input
terminal.
The input terminals are pulled down to the internal circuit’s A COM level by a resistor that is
approximately 100 k
Ω
. The maximum allowable voltage is 5 V. The logic threshold levels are
CMOS.
100 ms or greater
Input a signal with a pulse
interval of 100 ms or greater.
A COM
0 V
11
12
約100 kΩ
+5 V
TRIG INPUT
EXT CONT
Содержание PLZ1004WH
Страница 13: ...Installation and Preparation This chapter describes how to unpack and prepare this product before you use it 1 ...
Страница 28: ...28 PLZ 4WH Remote Sensing ...
Страница 29: ...Basic Functions This chapter explains the operations for each operation mode and other basic functions 2 ...
Страница 47: ...Advanced Operations This chapter explains ABC preset memory setup memory protection functions and the menu 3 ...
Страница 61: ...Sequences This chapter explains the sequence function Sequences 4 ...
Страница 83: ...External Control and Parallel Operation This chapter explains external control and Parallel Operation 5 ...
Страница 115: ...Maintenance This chapter describes the maintenance procedures including cleaning inspection and calibration 7 ...
Страница 127: ...8 Specifications This chapter contains the specifications and gives the dimensions of the PLZ 4WH ...
Страница 137: ...Appendix A Operating Area B Sequence Program Creation Table C Options ...