4
System Related Operation
Utility Menu Summary
122
U3606A User’s and Service Guide
Setting the output protection state
The OVP and OCP protection features depend on the output protection
state function. The output protection state must be enabled for the OVP
and OCP protection features to be active in the circuit. Disabling the
output protection state will deactivate both the OVP and OCP protection
features even if a trip level is set for either the OVP or OCP. See
Chapter 3, “Protection Functions,” starting on page 78
for more
information.
The following steps shows you how to enable or disable the output source
protection.
1
Press
Shift
>
Utility
to access the utility menu.
2
The first utility menu item (Error) will be shown in the upper
secondary display.
3
Press
or
until the menu item “triP Sby” is shown in the
secondary display as shown in the figure below.
4
Press
or
to switch between “YES” and “no”. Select “YES” to
enable the output protection state or “no” to disable the output
protection state.
N O T E
The output protection state does not affect the overvoltage and
overcurrent limits.
C A U T I O N
Disabling the output protection state may result in equipment damage
if an overvoltage or overcurrent condition occurs. It is recommended to
have the output protection state enabled.
Содержание U3606A
Страница 1: ...Keysight U3606A Multimeter DC Power Supply User s and Service Guide ...
Страница 2: ......
Страница 12: ...12 U3606A User s and Service Guide ...
Страница 128: ...3 DC Power Supply Operation Remote Sensing 106 U3606A User s and Service Guide ...
Страница 160: ...4 System Related Operation Remote Operation 138 U3606A User s and Service Guide ...
Страница 198: ...5 Verification and Performance Tests Additional Verification Tests 176 U3606A User s and Service Guide ...
Страница 242: ...6 Calibration Procedures Adjustments procedures 220 U3606A User s and Service Guide ...
Страница 291: ...List of Error Messages 9 Error Messages U3606A User s and Service Guide 269 ...