Oscilloscope Familiarization Labs
2
4000 X-Series Oscilloscopes Advanced Training Guide
23
The scope always performs measurements on the pulse located closest to
center-screen. In this case, the scope measures the positive pulse width of the 1st
pulse in this digital burst as shown in
. But what if we want to know the
widths of the 2nd, 3rd, 4th, etc., pulses?
15
Press the button in the Horizontal section of the front panel to turn on the
scope’s “zoom” display mode.
16
Set the Zoom timebase to
50.00 ns/div
by turning the large timebase knob.
17
Set the horizontal position/delay to
950.0 ns
in order to window-in on the 3rd
pulse.
When the “zoom” display is turned on, the horizontal controls (s/div and position)
control the zoomed (or expanded) timebase settings.
Figure 9
Measuring the positive pulse width of the 1st pulse in the burst.