Tap the
Bit
softkey and enter
1
in the keypad.
28
Tap the
0 1 X
softkey to select
0
for Bit 1.
29
Repeat Steps #27 and #28 until MOSI Data = 0000 0011.
Your scope should now be triggering on MOSI data = 03
HEX
with this byte shown
at center-screen similar to
. Let’s now capture a very long stream of SPI
traffic and then manually search through the captured and decoded record.
30
Press the
[Serial]
front panel key.
31
Tap the
Lister
softkey; then set the
Window
menu to select
Half-Screen
.
32
Set the scope’s timebase to
20.00 ms/div
.
33
Press
[Run/Stop]
to stop repetitive acquisitions.
34
Tap the
Scroll Lister
softkey; then turn the Entry knob to manually scroll through
the lister table. You can also scroll using the scroll bar on the right of the lister
window.
As you scroll through the data, note that waveforms “track”. This means that the
frame that the arrow points to in the lister table corresponds to the waveforms that
are positioned at center-screen. If you want to zoom in on a particular SPI frame of
Figure 57
Triggering on MOSI data = 03
HEX
.
Содержание 4000 X-Series
Страница 12: ...12 4000 X Series Oscilloscopes Advanced Training Guide 1 Getting Started...
Страница 156: ...156 4000 X Series Oscilloscopes Advanced Training Guide A Oscilloscope Block Diagram and Theory of Operation...
Страница 166: ...166 4000 X Series Oscilloscopes Advanced Training Guide B Oscilloscope Bandwidth Tutorial...
Страница 168: ...168 4000 X Series Oscilloscopes Advanced Training Guide C Related Keysight Literature...