Advanced Triggering, Search & Navigation, and Segmented Acquisition Labs
3
4000 X-Series Oscilloscopes Advanced Training Guide
53
Lab #9: Triggering on the Nth Pulse within a Burst using “Nth Edge
Burst” Trigger
In this lab you will learn how to use the scope’s “Nth Edge Burst” triggering mode
to trigger on pulses within a burst based on pulse count. Note that we will be
using the same training signal that we used in the previous lab.
1
Connect the channel-1 probe to the Demo 1 terminal and ground.
2
Press
[Default Setup]
on the scope’s front panel.
3
Press
[Help]
; then press the
Training Signals
softkey.
4
Open the
Training Signals: Sine
menu and double-tap the
Digital Burst with
Infrequent Glitch
signal.
5
Set channel-1’s vertical scaling to
1.00 V/div
.
6
Set channel-1’s offset/position to approximately
+1.7 V
in center the waveform
on-screen.
7
Set the trigger level to
+1.00 V
(~1 division above bottom of waveform).
8
Set the scope’s timebase to
500 ns/div
.
Figure 29
Capturing a digital burst using the scope’s default Edge triggering mode.
Содержание 4000 X-Series