Serial Bus Decoding & Triggering, Search & Navigation, and Segmented Acquisition Labs
4
4000 X-Series Oscilloscopes Advanced Training Guide
115
number of “found” events is indicated near the bottom of the display. To
automatically navigate to each LIN error, press the
and
front panel
navigation keys.
Let’s now use the scope’s Segmented Memory mode of acquisition to capture 500
consecutive occurrences of the LIN frame that the scope is currently set up to
trigger on (either ID = 21
HEX
or ID = 12
HEX
). But to complete the rest of this lab
your scope must be licensed with the Segmented Memory option.
26
Push the horizontal position/delay knob to re-position the trigger point back to
center-screen.
27
Set the scope’s timebase to
1.00 ms/div
.
28
Press the
[Run/Stop]
front panel to begin repetitive acquisition again.
29
Press the
[Acquire]
front panel key.
30
Tap the
Segmented
softkey; then tap
# of Segs
to set
500
as the number of
segments to capture.
31
Tap the
Segmented
softkey to begin a Segmented Memory acquisition. Note that
capturing this many consecutive occurrences of this particular frame will take
about 30 seconds.
32
Tap the
Current Segment
softkey; then turn the Entry knob to review all 500
captured segments. Tap it again to pull up the keypad to manually enter a
segment number.
33
Set the
Current Segment
to
500
and note the time-tag of the last captured
segment.
Содержание 4000 X-Series
Страница 12: ...12 4000 X Series Oscilloscopes Advanced Training Guide 1 Getting Started...
Страница 156: ...156 4000 X Series Oscilloscopes Advanced Training Guide A Oscilloscope Block Diagram and Theory of Operation...
Страница 166: ...166 4000 X Series Oscilloscopes Advanced Training Guide B Oscilloscope Bandwidth Tutorial...
Страница 168: ...168 4000 X Series Oscilloscopes Advanced Training Guide C Related Keysight Literature...