76
4000 X-Series Oscilloscopes Advanced Training Guide
3
Advanced Triggering, Search & Navigation, and Segmented Acquisition Labs
12
Tap the
Pattern
softkey; then select
1
as the pattern condition for D7.
13
Double-tap the
Channel
softkey to select
D6
.
14
Tap the
Pattern
softkey; then select
1
as the pattern condition for D6.
15
Repeat the above process until:
Pattern = 1 XXXX 4 D
15
XXXX XXXX 1110 0110 D
0
Your scope should now be triggering on logic pattern 1110 0110 (D7-D0), and the
top of the sine wave should be centered on-screen as shown in
. In
addition to displaying individual digital channels, this scope can also display all of
the digital channels of acquisition in an overlaid bus display mode while displaying
the HEX value of the bus. Let’s now set up the scope to show the bus display
mode.
16
Press the
[Digital]
front panel key; then tap the
Bus
softkey.
17
Double-tap the
Bus
softkey to enable the Bus1 bus display mode.
18
Set the scope’s timebase to
20.00 µs/div
.
Figure 47