Set the timebase to
20.00 µs/div
. Press the horizontal control knob to reset the
timebase.
32
Press the
[Acquire]
front panel key.
33
Tap the
Segmented
softkey; double-tap on
# of Segs
and set the value to
500
.
34
Press
[Run/Stop]
to restart signal acquisition.
35
Tap the
Segmented
softkey to begin a Segmented Memory acquisition. This may
take a moment as the scope is processing and analyzing 500 packets and
associated screen space.
36
Tap the
Current Segment
softkey; then turn the Entry knob to review all 500
captured segments.
37
Set the
Current Segment
to
500
and note the time-tag of the last captured
segment.
Segmented Memory optimizes oscilloscope acquisition memory by only capturing
important segments of a waveform based on the trigger condition and timebase
setting. In this example, we have selectively captured approximately 400 ms of
total acquisition time as shown in
. Note that we can also view the
decoded USB data in the "lister" format, and we can also perform Search &
Navigation on the segments. This particular example is limited since all the frames
are identical, but the exercise should provide insight on how segmented memory
can be advantageous to debugging USB signals.
Содержание 4000 X-Series
Страница 12: ...12 4000 X Series Oscilloscopes Advanced Training Guide 1 Getting Started...
Страница 156: ...156 4000 X Series Oscilloscopes Advanced Training Guide A Oscilloscope Block Diagram and Theory of Operation...
Страница 166: ...166 4000 X Series Oscilloscopes Advanced Training Guide B Oscilloscope Bandwidth Tutorial...
Страница 168: ...168 4000 X Series Oscilloscopes Advanced Training Guide C Related Keysight Literature...