LIST OF
WARNINGS AND CAUTIONS
BOP 1KW OPR 11/13/15
G/(H Blank)
PAGE
WARNING/CAUTION
3-1
CAUTION:
Before connecting a load, note that the unit is will power-up with the con-
figuration set by the power-up switches accessible through the top cover
(see Table 2-2 for switch settings). Verify that these power-up settings are
compatible with your load (see Figure 2-2 and Table 2-2 for switch set-
tings).
To change to change load type, baud rate or Trigger port Remote on/off
logic refer to PAR. 3.3.2.1; to change all other power-up settings listed be-
low refer to PAR. 3.3.2.2.
In addition to the power-up settings determined by the switches ac-
cessed through the top cover, many unit parameters may be saved for the
next power-up cycle using MEM:UPD commands (see PAR. B.12). When
using MEM:UPD, it is recommended that the unit be tagged with the cus-
tom power-up configuration to avoid unexpected behavior upon power-
up.
3-4
CAUTION:
DO NOT repeatedly toggle the circuit breaker/switch as this may damage
the unit.
3-5
CAUTION:
DO NOT repeatedly toggle the circuit breaker/switch as this may damage
the unit.
3-7
CAUTION:
When working with active loads, always adjust the BOP protection limits
to be above the maximum values of voltage or current expected from the
load. For example, when the BOP is operating in voltage mode sinking
energy from a constant current type load, set the current protection limits
of the BOP above the maximum current expected from the load.
3-22
CAUTION:
The commands listed above with (**) will generate a “-440, Missing Que-
ry” error if a query does not precede the command in the same command
string or
;*OPC?
does not follow the command. Although commands not
marked with (**) will not generate an error, all commands listed above re-
quire verification to insure absolute success. Failure to follow these
rules can result in the loss of all stored constants and render the unit in-
operative.
3-23
CAUTION:
If you are not sure what the saved settings are, disconnect the load be-
fore issuing *RCL. Then issue queries to identify the stored settings.
3-34
CAUTION:
When the serial port has received an XOFF, the error message -400, “Que-
ry Error” will be placed in the queue to indicate the loss of transmitted in-
formation due to a received XOFF character. When XON is received, the
unit will transmit all data in it's buffer followed by the exclamation char-
acter (!). This (!) character is not part of any message from the BOP and
indicates the transmission buffer has been cleared and the BOP is idle.
B-5
CAUTION:
When using MEM:UPD it is recommended that the unit be tagged with the
saved configuration to avoid unexpected behavior upon power-up.