1-4
BOP-1K-GL 111315
OUTPUT CHARACTERISTICS (Continued)
Error sensing
0.25V or 1% of voltage rating per
wire (whichever is less)
Above rated output voltage(3)
Transient recovery in
voltage mode
maximum excursion
5% of nominal output
nominal voltage, 50% load step
Recovery time
350
sec
Return within 1% of set voltage
Output isolation voltage
d-c or p-p
300V (500V for BOP 10-100GL)
Output to chassis ground
d-c leakage current
0.1mA @ 300V
(0.1mA @ 500V for BOP 10-100GL)
GND-NET to GND link not installed. (4)
Series operation
Master/slave
Maximum of 2 identical units. (5)(6)
Parallel operation
Master/slave
Maximum of 2 identical units (5)(6)
(maximum of 3 for BOP 10-100GL)
Power-up Timing
Series or parallel
systems
15 sec. max.
Time required for system to be able to
respond to analog or digital control.
Output Protection
limiting
Analog
Voltage and current limited in four quadrants, adjustable
between 10% and 101% of EO
NOM
or IO
NOM
Digital
Voltage and current limited in four quadrants, adjustable between ±Internal minimum
EO
MIN
or IO
MIN
(box) (see Figure 1-3) and ±1.01 EO
NOM
or IO
NOM
.
Output Stage Protection
Output overvoltage/overcurrent
Heatsink overtemperature,
switchers overcurrent
Triggers latched shutdown protection of the
output module and PFC stage. Recover by
cycling power off, then on.
Input Stage Protection (PFC)
Internal overvoltage, undervoltage,
overcurrent, heat sink
overtemperature, fan inoperative
Input circuit breaker overcurrent
Trips circuit breaker to shut off unit
Small signal
Bandwidth for main
channel (analog or
digital)
voltage channel
1 KHz minimum
Into nominal resistive load, 10% of rating
current channel
800 Hz minimum
Into short circuit, 10% of rating
Rise/Fall time
voltage channel
475
Sec
Into nominal resistive load, measured from 10
to 90%, from 0 to ±100% of rating
current channel
500
Sec
Into short circuit, measured from 10 to 90%,
from 0 to ±100% of rating
External limit channels update rate
100mS max
Voltage or current, positive and negative limit
values
(3) Remote error sensing applies to the main voltage channel. Feedback for the ±voltage limit channels is supplied locally
from the power terminals. Consult factory for a remote sensing solution applicable to the voltage limit channels.
(4) With GND-NET to GND link installed: 0.55mA at 300V (0.91mA at 500V for BOP 10-100GL).
(5) Consult factory to configure more than two units in series or parallel (three units for BOP 10-100GL in parallel).
(6) For multiple unit configurations, automatic shutdown upon accidental removal of the cable at the Master PAR/SER IN
PROTECT PORT can be implemented with a simple internal modification. Consult factory for details.
TABLE 1-2. BOP GENERAL SPECIFICATIONS (Continued)
SPECIFICATION
RATING/DESCRIPTION