BOP-1K-GL 111315
3-25
3.5.7.2
UNDERSTANDING HOW WAVEFORMS ARE GENERATED
Waveform are generated by the BOP by producing a series of discrete output levels (points) in a
prescribed pattern. In the case of sine, triangle and ramps, this produces an output that con-
forms to an approximation of the selected waveform type. The number of points available for a
waveform is limited to 3933 for all segments. Since there are a finite number of points, the lower
the frequency, the more points used, and the smoother the output waveform will appear. As the
frequency increases, fewer points are available for each cycle and the resulting waveform may
appear somewhat more jagged. Tables 3-4 and 3-5 list the number of points used for each fre-
quency range of sine, triangle and ramp waveforms and for square waveforms, respectively.
Levels use a maximum of 60 points.
This means that a waveform consisting of a single sinewave segment at 0.1 Hz will use all 3840
points to generate each cycle, while a sinewave at 440 Hz will use 24 points for each cycle.
Note that a single segment between 0.01Hz and 1.8Hz uses all available points, so subsequent
segments will result in an error “-223, “too much data” and some points may appear in the list.
This can be corrected by either reducing the number of segments, or increasing the frequency
of the existing segments until the point total is acceptable.
TABLE 3-4. SINE, TRIANGLE AND RAMP WAVEFORM FREQUENCY VS. POINTS
Frequency
(See Notes 1, 2, and 3)
Total Points
Frequency
(See Notes 1, 2, and 3)
Total Points
From
To
From
To
0.01Hz
2.7Hz
3840
55.5Hz
66.5Hz
160
2.71Hz
3.6Hz
2880
66.6Hz
88.7Hz
120
3.71Hz
5.5Hz
1920
88.8Hz
118.3Hz
90
5.6Hz
8.3Hz
1280
118.4Hz
147.9Hz
72
8.4Hz
11.0Hz
960
148Hz
177.4Hz
60
11.1Hz
14.7Hz
720
177.5Hz
221.8Hz
48
14.8Hz
22.1Hz
480
221.9Hz
295.8Hz
36
22.2Hz
33.2Hz
320
295.81Hz
354.9Hz
30
33.3Hz
44.3Hz
240
355.9Hz
443.7Hz
24 (See Note 2)
44.4Hz
55.4Hz
192
443.8z
532Hz
20 (See Note 3)
NOTES: 1. As the frequency varies within the range, the time interval per point varies proportionately,
decreasing as the frequency increases.
2. Sine and Triangle segments can not exceed 443Hz.
3. Ramp segments can not exceed 532Hz.