BOP-1KW-GL 111315
B-27
B.87
[SOURce:]VOLTage[:LEVel][:IMMediate][:AMPlitude]? QUERY
VOLT?
Syntax:
Short Form: [SOUR:]VOLT[:LEV][:IMM][:AMP]? {MIN | MAX}
Long Form: [SOURce:]VOLTage[:LEVel][:IMMediate][:AMPlitude]? {MIN | MAX}
Description:
Identifies programmed voltage, maximum allowable voltage, or minimum voltage.
The VOLT?
query returns the programmed value of voltage. Actual output voltage will depend on load conditions.
The VOLT?MAX query returns the maximum voltage allowed for a particular model. VOLT? MIN
returns minimum voltage allowed for power supply (always negative).
Related Commands:
VOLT.
(See example, Figure B-1.)
B.88
[SOURce:]VOLTage[:LEVel]:LIMit[:BOTH] COMMAND
VOLT:LIM[:BOTH]
Syntax:
Short Form: [SOUR:]VOLT[:LEV]:LIM[:BOTH] <value>
Long Form: [SOURce:]VOLTage[:LEVel]:LIMit[:BOTH] <value>
where <value> is between zero and rated (nominal) output voltage
Description: Establishes the software limit <value> for output voltage, i.e., sets the maximum value of positive or
negative output voltage that the unit will be allowed to produce. Requires MEM:UPD (PAR. B.12) to
save for power up. See PAR. 3.5.5.2 and Figure 3-6 for special programming considerations.
B.89
[SOURce:]VOLTage[:LEVel]:LIMit[:BOTH]? QUERY
VOLT:LIM[:BOTH]?
Syntax:
Short Form: [SOUR:]VOLT[:LEV]:LIM[:BOTH]?
Long Form: [SOURce:]VOLTage[:LEVel]:LIMit:[:BOTH]?
Returns <value>
Description: Identifies the software limit value for both positive and negative output voltage specified by the user.
B.90
[SOURce:]VOLTage[:LEVel]:LIMit:NEGative COMMAND
VOLT:LIM:NEG
Syntax:
Short Form: [SOUR:]VOLT[:LEV]:LIM:NEG <value>
Long Form: [SOURce:]VOLTage[:LEVel]:LIMit:NEGative <value>
where <value> is between zero and rated (nominal) output voltage
Description: Establishes the software limit <value> for negative output voltage, i.e., sets the maximum value of
negative output voltage that the unit will be allowed to produce. Requires MEM:UPD (PAR. B.12) to
save for power up. See PAR. 3.5.5.2 and Figure 3-6 for special programming considerations.
B.91
[SOURce:]VOLTage[:LEVel]:LIMit:NEGative? QUERY
VOLT:LIM:NEG?
Syntax:
Short Form: [SOUR:]VOLT[:LEV]:LIM:NEG? <value>
Long Form: [SOURce:]VOLTage[:LEVel]:LIMit:NEGative? <value>
Description: Identifies the software limit value for negative output voltage specified by the user.
B.92
[SOURce:]VOLTage[:LEVel]:LIMit:POSitive COMMAND
VOLT:LIM:POS
Syntax:
Short Form: [SOUR:]VOLT[:LEV]:LIM:POS <value>
Long Form: [SOURce:]VOLTage[:LEVel]:LIMit:POSitive <value>
where <value> is between zero and rated (nominal) output voltage
Description: Establishes the software limit <value> for positive output voltage, i.e., sets the maximum value of pos-
itive output voltage that the unit will be allowed to produce. Requires MEM:UPD (PAR. B.12) to save
for power up. See PAR. 3.5.5.2 and Figure 3-6 for special programming considerations.
B.93
[SOURce:]VOLTage[:LEVel]:LIMit:POSitive? QUERY
VOLT:LIM:POS?
Syntax:
Short Form: [SOUR:]VOLT[:LEV]:LIM:POS? <value>
Long Form: [SOURce:]VOLTage[:LEVel]:LIMit:POSitive? <value>
Description: Identifies the software limit value for positive output voltage specified by the user.
Содержание BOP-GL 1KW
Страница 2: ......
Страница 10: ......
Страница 20: ...x BOP 1K 111315 FIGURE 1 1 HIGH POWER BOP GL SERIES POWER SUPPLY...
Страница 36: ...1 16 BOP 1K GL 111315 FIGURE 1 3 BOP OUTPUT CHARACTERISTICS...
Страница 38: ......
Страница 116: ......
Страница 128: ......
Страница 174: ......