10-18
Triggering
While operating within the trigger model (ARM indicator on), most commands will not be
executed until the SourceMeter completes all of its programmed source-measure operations
and returns to the idle state. The IFC (interface clear), SDC (selected device clear) and DCL
(device clear) commands can be executed under any circumstance while operating within the
trigger model. They will abort any other command or query.
•
:ABORt
•
:SYSTem:PRESet
•
*TRG or GET
•
*RST
•
*RCL
NOTE
SDC, DCL, or :ABORt place the SourceMeter in the idle state. For fastest response,
use SDC or DCL to return to idle.
Event detection
Once the instrument is taken out of idle, operation proceeds through the trigger model to
perform the Source, Delay, and Measure actions.
In general, operation is held up at an event detector until the programmed event occurs. Note
however, that if an event detector has a bypass (:DIRection), operation can be programmed to
loop around the event detector.
Arm layer
Event Detector Bypass
—
As shown in Figure 10-9, there is a bypass (ARM:DIRection)
for the Arm Event Detector. This bypass can only be used if TLINk, PSTest, NSTest, or BSTest
is the selected Arm-In Event. The bypass serves to
“
jump-start
”
operation. With the bypass set
to SOURce, operation will loop around the Arm Event Detector when an INITiate command is
sent (assuming the output is turned ON).
The programmable arm-in events for the Arm Layer are described as follows:
IMMediate
—
Event detection occurs immediately allowing operation to continue.
BUS
—
Event detection occurs when a bus trigger (GET or *TRG) is received.
TIMer
—
Event detection occurs immediately on the initial pass through the trigger model.
Each subsequent detection is satis
fi
ed when the programmed timer interval elapses. The timer
resets to its initial state when the instrument goes into idle.
MANual
—
Event detection occurs when the TRIG key is pressed. The SourceMeter must
be in LOCAL mode for it to respond to the TRIG key. Press the LOCAL key or send LOCAL
24 over the bus to take the SourceMeter out of remote.
TLINk
—
Event detection occurs when an input trigger via the Trigger Link input line is
received (see
Trigger Link
for more information). With TLINk selected, you can loop around
the Arm Event Detector by setting the event detector bypass (ARM:DIRection) to SOURce.
Содержание 6430
Страница 26: ......
Страница 32: ......
Страница 78: ...2 14 Connections ...
Страница 98: ...3 20 Basic Source Measure Operation ...
Страница 138: ...5 30 Source Measure Concepts ...
Страница 156: ...6 18 Range Digits Speed and Filters ...
Страница 168: ...7 12 Relative and Math ...
Страница 176: ...8 8 Data Store ...
Страница 202: ...9 26 Sweep Operation ...
Страница 248: ...11 22 Limit Testing ...
Страница 310: ...16 6 SCPI Signal Oriented Measurement Commands ...
Страница 418: ...17 108 SCPI Command Reference ...
Страница 450: ...18 32 Performance Verification ...
Страница 477: ...A Specifications ...
Страница 489: ...B StatusandErrorMessages ...
Страница 498: ...B 10 Status and Error Messages ...
Страница 499: ...C DataFlow ...
Страница 503: ...D IEEE 488BusOverview ...
Страница 518: ...D 16 IEEE 488 Bus Overview ...
Страница 519: ...E IEEE 488andSCPI ConformanceInformation ...
Страница 523: ...F MeasurementConsiderations ...
Страница 539: ...G GPIB488 1Protocol ...
Страница 557: ......