Page 7.15 - 4
COMBIVERT F5-A, -E, -H
© KEB, 2012-10
Special functions
Pn.28: DC braking mode
Bit
Meaning
Value
Explanation
0...3
DC Braking
Mode
0: no DC braking
DC braking is never triggered
1: no direction of ro-
tation and actual va-
lue = 0
DC braking, if the setpoint reaches 0 rpm after the ramp generator
(ru.02 "display ramp output") and the rotation setting is missing.
The braking time is determined by Pn.30 (independent of the ac-
tual speed). If the rotation setting is applied again, the DC braking
is aborted.
2: disabling the di-
rection of rotation
DC braking after removal of the rotation setting. The braking time
is dependent on Pn.30 and the actual frequency.
1, 2
Re-application of the rotation setting does not abort the DC bra-
king.
3: Change of direc-
tion of rotation
DC braking as soon as the rotation setting changes (different di-
rection of rotation or no setting). The braking time is dependent on
Pn.30 and the actual frequency (ru.03).
1, 2
Re-application of the rotation setting does not abort the DC bra-
king.
4: no direction of ro-
tation and actual va-
lue < Pn.32
DC braking if the actual frequency ru.03
2
is lower than Pn.32 "DC
braking start level" and the rotation setting is missing. The braking
time is dependent on Pn.30 and Pn.32
3
Re-application of the rotation setting does not abort the DC bra-
king.
5: Deceleration and
actual value < Pn.32
DC braking if the actual frequency ru.03
1
is lower than Pn.32 "DC
braking start level" and the rotation setting is missing. The braking
time is dependent on Pn.30 and Pn.32
3
Re-application of the rotation setting does not abort the DC bra-
king.
6: Setpoint < Pn.32
The set value before the ramp generator (ru.01 "set value display)
is smaller than Pn.32 "DC braking start level". The braking time is
dependent on Pn.30 and the actual frequency (ru.03).
1, 2
To leave the status „22: standstill after DC braking“, ru.01 must be
higher than Pn.32 + LE.16 „operating hysteresis“. An increase of
the setpoint does not abort the DC braking.
7: Digital input time-
limited
DC braking, as soon as an input programmed to DC brake (Pn.29)
is active. The braking time is dependent on Pn.30 and the actual
frequency (ru.03).
1, 2
restart only after the input is deactivated.
8: as long as the di-
gital input is set
DC-braking as long as an input programmed to DC-braking is ac-
tive.
9: at start of the mo-
dulation
DC braking after modulation release (direction of ro con-
trol release) for the time Pn.30.
10: Conditions
DC braking according to the conditions programmed in bit 4..7.
The braking time is equal to Pn.30 "DC-brake time"
4
16: DCB after nop
DC braking after status "0: no control release"
4
5
32: DCB at switch on DC braking after power-on-reset (power on)
4
6
64: DCB for auto-
retry
DC braking after automatic restart
4
7
128: DCB after LS
DC braking after status "70: standstill"
4
Содержание COMBIVERT F5-A
Страница 1: ...KEB COMBIVERT F5 A E H 4 4 APPLICATION MANUAL Mat No Rev 00F5AEA K440 1A...
Страница 2: ...Page 1 1 2 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Страница 4: ...Page 1 1 4 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Страница 14: ...Page 1 1 14 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Страница 20: ...Page 2 1 6 COMBIVERT F5 A E H KEB 2012 10 Product Overview...
Страница 28: ...Page 3 1 8 COMBIVERT F5 A E H KEB 2012 10 Control Units...
Страница 34: ...Page 4 1 6 COMBIVERT F5 A E H KEB 2012 10 Fundamentals...
Страница 40: ...Page 4 2 6 COMBIVERT F5 A E H KEB 2012 10 Password input...
Страница 42: ...Page 5 1 2 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Страница 46: ...Page 5 1 6 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Страница 70: ...Page 6 2 20 COMBIVERT F5 A E H KEB 2012 10 Start up...
Страница 140: ...Page 7 3 44 COMBIVERT F5 A E H KEB 2012 10 Digital in and outputs...
Страница 200: ...Page 7 5 38 COMBIVERT F5 A E H KEB 2012 10 Motor data and controller adjustments of the asynchronous motor...
Страница 207: ...Motor data and controller adjustments of the synchronous motor KEB 2012 10 COMBIVERT F5 A E H Page 7 6 7 7...
Страница 238: ...Page 7 7 12 COMBIVERT F5 A E H KEB 2012 10 Speed control...
Страница 254: ...Page 7 8 16 COMBIVERT F5 A E H KEB 2012 10 Torque display and limiting...
Страница 260: ...Page 7 9 6 COMBIVERT F5 A E H KEB 2012 10 Torque control...
Страница 292: ...Page 7 11 26 COMBIVERT F5 A E H KEB 2012 10 Speed measurement...
Страница 432: ...Page 7 14 14 COMBIVERT F5 A E H KEB 2012 10 Parameter sets...
Страница 466: ...Page 7 15 34 COMBIVERT F5 A E H KEB 2012 10 Special functions...
Страница 478: ...Page 7 16 12 COMBIVERT F5 A E H KEB 2012 10 CP Parameter definition...
Страница 480: ...Page 8 1 2 COMBIVERT F5 A E H KEB 2012 10 Troubleshooting 8 1 1 General 8 1 3 8 1 2 Error Messages and their Cause 8 1 3...
Страница 488: ...Page 8 1 10 COMBIVERT F5 A E H KEB 2012 10 Troubleshooting...
Страница 496: ...Page 9 1 8 COMBIVERT F5 A E H KEB 2012 10 General design...
Страница 538: ...Page 11 1 28 COMBIVERT F5 A E H KEB 2012 10 Parameter...
Страница 540: ...Page 12 1 2 COMBIVERT F5 A E H KEB 2008 02 Annex 12 1 1 Index 12 1 3...