Page 7.6 - 22
COMBIVERT F5-A, -E, -H
© KEB, 2012-10
Motor data and controller adjustments of the synchronous motor
HF supply
The rotor position can be determined continuously with a test signal for operation at standstill and low speed.
HF supply is only possible with a switching frequency of 8 or 16 kHz. The power unit must supply the required
current also at 0 Hz and 8 or 16 kHz.
The internal FoH filter is used for HF supply. The default values of parameters fh.01... fh.09 are preset to 1 kHz
with quality factor 5. If the HF injection is used the speed controller must be adjusted a little softer.
Since the HF supply has only advantages in the lower speed range, it is switched off above nn.03. When falling
below nn.02 the HF supply is switched on again. The HF supply is advantageous only in lower speed range if
there are problems with the motor model.
nn.14 HF supply amplitude
The signal amplitude of the HF supply can be modified here. A higher value means more information, but also
higher losses and a higher noise level.
The default value is selected by way that 1/8 of the rated motor current is used. But maximally 25% of the ma-
ximum output voltage.
nn.15 HF supply optimization
The Pi-controller for speed determination at HF injection can be modified here. This Pi-controller is paramete
-
rized by dr.31, dr.64, nn.14 and nn.15.
nn.17 speed limit open-loop operation
The speed limit for the speed limit open-loop operation is now separately adjustable from the additional ramp via nn.17. In
order that all remains downward compatible, nn.08 is still active for the speed limit open-loop operation, if nn.17 is set to 0.
Содержание COMBIVERT F5-A
Страница 1: ...KEB COMBIVERT F5 A E H 4 4 APPLICATION MANUAL Mat No Rev 00F5AEA K440 1A...
Страница 2: ...Page 1 1 2 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Страница 4: ...Page 1 1 4 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Страница 14: ...Page 1 1 14 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Страница 20: ...Page 2 1 6 COMBIVERT F5 A E H KEB 2012 10 Product Overview...
Страница 28: ...Page 3 1 8 COMBIVERT F5 A E H KEB 2012 10 Control Units...
Страница 34: ...Page 4 1 6 COMBIVERT F5 A E H KEB 2012 10 Fundamentals...
Страница 40: ...Page 4 2 6 COMBIVERT F5 A E H KEB 2012 10 Password input...
Страница 42: ...Page 5 1 2 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Страница 46: ...Page 5 1 6 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Страница 70: ...Page 6 2 20 COMBIVERT F5 A E H KEB 2012 10 Start up...
Страница 140: ...Page 7 3 44 COMBIVERT F5 A E H KEB 2012 10 Digital in and outputs...
Страница 200: ...Page 7 5 38 COMBIVERT F5 A E H KEB 2012 10 Motor data and controller adjustments of the asynchronous motor...
Страница 207: ...Motor data and controller adjustments of the synchronous motor KEB 2012 10 COMBIVERT F5 A E H Page 7 6 7 7...
Страница 238: ...Page 7 7 12 COMBIVERT F5 A E H KEB 2012 10 Speed control...
Страница 254: ...Page 7 8 16 COMBIVERT F5 A E H KEB 2012 10 Torque display and limiting...
Страница 260: ...Page 7 9 6 COMBIVERT F5 A E H KEB 2012 10 Torque control...
Страница 292: ...Page 7 11 26 COMBIVERT F5 A E H KEB 2012 10 Speed measurement...
Страница 432: ...Page 7 14 14 COMBIVERT F5 A E H KEB 2012 10 Parameter sets...
Страница 466: ...Page 7 15 34 COMBIVERT F5 A E H KEB 2012 10 Special functions...
Страница 478: ...Page 7 16 12 COMBIVERT F5 A E H KEB 2012 10 CP Parameter definition...
Страница 480: ...Page 8 1 2 COMBIVERT F5 A E H KEB 2012 10 Troubleshooting 8 1 1 General 8 1 3 8 1 2 Error Messages and their Cause 8 1 3...
Страница 488: ...Page 8 1 10 COMBIVERT F5 A E H KEB 2012 10 Troubleshooting...
Страница 496: ...Page 9 1 8 COMBIVERT F5 A E H KEB 2012 10 General design...
Страница 538: ...Page 11 1 28 COMBIVERT F5 A E H KEB 2012 10 Parameter...
Страница 540: ...Page 12 1 2 COMBIVERT F5 A E H KEB 2008 02 Annex 12 1 1 Index 12 1 3...