Page 7.11 - 18
COMBIVERT F5-A, -E, -H
© KEB, 2012-10
Speed measurement
2, 3
Actual value
0: 256 inc
Number of increments per revolution which are output over the enco-
der emulation channel with the adjustment „source = 2: actual value“.
4: 512 inc
8: 1024 inc
12: 2048 inc
4...7
Division
0: direct
The increments of encoder channel 1 are directly output via the en-
coder emulation.
Use this adjustment always if „source = 2: actual value“ is parame-
terized.
16: 2
The increments of encoder channel 1 are divided by the selected
factor (2, 4, 8,…).
Attention: The zero signal is not divided.
It is output once per revolution. Also the pulse duration of the zero
signal is not changed compared to the direct output. Thus it is shorter
than the divided trace A and B signals.
32: 4
48: 8
64: 16
80: 32
96: 64
112: 128
7.11.10
Absolute position (encoder 1)
7.11.10.1 Position
values
The position values of encoder 1 and 2 are determined as follows.
Z/N
ec.33
ec.60
ec.29
ec.4/ec.5 or ec.56/57
Z/N
ec.34
ec.61
ec.30
ec.14/ec.15 or ec.58/59
ru.54
ch 1
ch 2
-
-
ec.6
ec.16
see chapter
Encoder gear factor
see chapter
Encoder gear factor
see chapter
Posi / Syn
7.11.10.2 System
offset
The system offset is used to:
• set the actual position to the reference point
• Compensate overflows at multiturn encoders after power-on
Содержание COMBIVERT F5-A
Страница 1: ...KEB COMBIVERT F5 A E H 4 4 APPLICATION MANUAL Mat No Rev 00F5AEA K440 1A...
Страница 2: ...Page 1 1 2 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Страница 4: ...Page 1 1 4 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Страница 14: ...Page 1 1 14 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Страница 20: ...Page 2 1 6 COMBIVERT F5 A E H KEB 2012 10 Product Overview...
Страница 28: ...Page 3 1 8 COMBIVERT F5 A E H KEB 2012 10 Control Units...
Страница 34: ...Page 4 1 6 COMBIVERT F5 A E H KEB 2012 10 Fundamentals...
Страница 40: ...Page 4 2 6 COMBIVERT F5 A E H KEB 2012 10 Password input...
Страница 42: ...Page 5 1 2 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Страница 46: ...Page 5 1 6 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Страница 70: ...Page 6 2 20 COMBIVERT F5 A E H KEB 2012 10 Start up...
Страница 140: ...Page 7 3 44 COMBIVERT F5 A E H KEB 2012 10 Digital in and outputs...
Страница 200: ...Page 7 5 38 COMBIVERT F5 A E H KEB 2012 10 Motor data and controller adjustments of the asynchronous motor...
Страница 207: ...Motor data and controller adjustments of the synchronous motor KEB 2012 10 COMBIVERT F5 A E H Page 7 6 7 7...
Страница 238: ...Page 7 7 12 COMBIVERT F5 A E H KEB 2012 10 Speed control...
Страница 254: ...Page 7 8 16 COMBIVERT F5 A E H KEB 2012 10 Torque display and limiting...
Страница 260: ...Page 7 9 6 COMBIVERT F5 A E H KEB 2012 10 Torque control...
Страница 292: ...Page 7 11 26 COMBIVERT F5 A E H KEB 2012 10 Speed measurement...
Страница 432: ...Page 7 14 14 COMBIVERT F5 A E H KEB 2012 10 Parameter sets...
Страница 466: ...Page 7 15 34 COMBIVERT F5 A E H KEB 2012 10 Special functions...
Страница 478: ...Page 7 16 12 COMBIVERT F5 A E H KEB 2012 10 CP Parameter definition...
Страница 480: ...Page 8 1 2 COMBIVERT F5 A E H KEB 2012 10 Troubleshooting 8 1 1 General 8 1 3 8 1 2 Error Messages and their Cause 8 1 3...
Страница 488: ...Page 8 1 10 COMBIVERT F5 A E H KEB 2012 10 Troubleshooting...
Страница 496: ...Page 9 1 8 COMBIVERT F5 A E H KEB 2012 10 General design...
Страница 538: ...Page 11 1 28 COMBIVERT F5 A E H KEB 2012 10 Parameter...
Страница 540: ...Page 12 1 2 COMBIVERT F5 A E H KEB 2008 02 Annex 12 1 1 Index 12 1 3...