
Page 7.3 - 38
COMBIVERT F5-A, -E, -H
© KEB, 2012-10
Digital in- and outputs
do.00...do.07: Switching conditions
V a -
lue
Function
Description
95
Drive in target window
At active contouring drive generally the target position ru.61 is adjusted. The
switching condition is generally not fulfilled as long as the approach to refe
-
rence point is not completed. It is fulfilled, if the contouring drive is active.
Otherwise, the actual position is always compared with the target position.
The condition is fulfilled, if the drive is in the target window PS.30.
96
Blockade active
The setpoint must be above the level (Pn.86). If the actual value is below the
level, a counter counts up until the time is up (Pn.87).
97
Warning encoder 1
The switching condition is the splitting of switching condition 91: Warning
encoder
98
Warning encoder 2
The switching condition is the splitting of switching condition 91: Warning
encoder
99
Warning flow control
The switching condition is set if there is an error in the flow control or if there
is no flow or constant flow for the adjusted deceleration time (Pn.94).
100
Combination of different condi-
tions
Combination condition; Error or OL-pre-warning or OH-pre-warning or (Sta-
tus POFF or PLS) and Fout=0Hz)
Speed change during scan time
————————————————————
60 x scan time (in seconds)
* acceleration =
Comparison level 0...7, LE.00...LE.07
These parameters define the levels of the switching conditions.
Level 0 (LE.0) applies for switching condition 0; LE.1 for switching condition 1 ... and so forth.
Hysteresis 0...7, LE. 08...LE.15
The hysteresis
in reference to the adjusted values, define parameters LE. 08...LE.15.
Hysteresis 0 (LE.08) applies for comparison level 0; LE.09 for comparison level 1 ... and so forth.
Frequency hysteresis LE.16
LE.16 defines
the hysteresis for the status constant-run.
7.3.18 Inverting of switching conditions for
flags
0...7 (do.08...do.15)
Picture 7.3.15 Inverting and selecting the switching conditions
8
do.24
1
1
1
1
do.8...do.15
do.0
do.1
do.2
do.3
do.4
do.5
do.6
do.7
1
2
4
8
16
32
64
128
do.16...do.23
1
2
4
8
16
32
64
128
1
1
1
1
Содержание COMBIVERT F5-A
Страница 1: ...KEB COMBIVERT F5 A E H 4 4 APPLICATION MANUAL Mat No Rev 00F5AEA K440 1A...
Страница 2: ...Page 1 1 2 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Страница 4: ...Page 1 1 4 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Страница 14: ...Page 1 1 14 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Страница 20: ...Page 2 1 6 COMBIVERT F5 A E H KEB 2012 10 Product Overview...
Страница 28: ...Page 3 1 8 COMBIVERT F5 A E H KEB 2012 10 Control Units...
Страница 34: ...Page 4 1 6 COMBIVERT F5 A E H KEB 2012 10 Fundamentals...
Страница 40: ...Page 4 2 6 COMBIVERT F5 A E H KEB 2012 10 Password input...
Страница 42: ...Page 5 1 2 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Страница 46: ...Page 5 1 6 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Страница 70: ...Page 6 2 20 COMBIVERT F5 A E H KEB 2012 10 Start up...
Страница 140: ...Page 7 3 44 COMBIVERT F5 A E H KEB 2012 10 Digital in and outputs...
Страница 200: ...Page 7 5 38 COMBIVERT F5 A E H KEB 2012 10 Motor data and controller adjustments of the asynchronous motor...
Страница 207: ...Motor data and controller adjustments of the synchronous motor KEB 2012 10 COMBIVERT F5 A E H Page 7 6 7 7...
Страница 238: ...Page 7 7 12 COMBIVERT F5 A E H KEB 2012 10 Speed control...
Страница 254: ...Page 7 8 16 COMBIVERT F5 A E H KEB 2012 10 Torque display and limiting...
Страница 260: ...Page 7 9 6 COMBIVERT F5 A E H KEB 2012 10 Torque control...
Страница 292: ...Page 7 11 26 COMBIVERT F5 A E H KEB 2012 10 Speed measurement...
Страница 432: ...Page 7 14 14 COMBIVERT F5 A E H KEB 2012 10 Parameter sets...
Страница 466: ...Page 7 15 34 COMBIVERT F5 A E H KEB 2012 10 Special functions...
Страница 478: ...Page 7 16 12 COMBIVERT F5 A E H KEB 2012 10 CP Parameter definition...
Страница 480: ...Page 8 1 2 COMBIVERT F5 A E H KEB 2012 10 Troubleshooting 8 1 1 General 8 1 3 8 1 2 Error Messages and their Cause 8 1 3...
Страница 488: ...Page 8 1 10 COMBIVERT F5 A E H KEB 2012 10 Troubleshooting...
Страница 496: ...Page 9 1 8 COMBIVERT F5 A E H KEB 2012 10 General design...
Страница 538: ...Page 11 1 28 COMBIVERT F5 A E H KEB 2012 10 Parameter...
Страница 540: ...Page 12 1 2 COMBIVERT F5 A E H KEB 2008 02 Annex 12 1 1 Index 12 1 3...