Motor data and controller adjustments of the asynchronous motor
© KEB, 2012-10
COMBIVERT F5-A, -E, -H
Page 7.5 - 25
7
Resolution mode
dS.21
max. dS.22
4000 rpm
1/12 rated speed
1 s
8000 rpm
1/12 rated speed
2 s
16000 rpm
1/12 rated speed
4 s
32000 rpm
1/12 rated speed
8 s
64000 rpm
1/12 rated speed
16 s
128000 rpm
1/12 rated speed
32 s
•
Leakage inductance:
Measurement of the leakage inductance can lead to wrong values, if the inductance of the motor has a
pronounced current dependence. The current has a „bell-shaped“ curve at setting of sine-wave voltage.
This can often be observed at spindle motors. The magnetising current can be watched via Combivis in
ru.87 during the rotor
resistance measurement, to find out whether the motor to be
start up is concerned.
Depending on the deviation of the current from the sine form the inductance is reduced to 85..70% of the
identified
value.
•
Check current controller adjustments
A correction of the
current controller adjustment is eventually necessary if the identified leakage in
-
ductance (ds.07) is < 1,4mH:
ds.00 = ds.00_def * 1,0…1,5
ds.01 = ds.01_def * 1,5…2
Control to model currents:
The motor model (dS.04 bit 0) must be active for this. Control to the model current (dS.18 bit 3) has the advan-
tage that
disturbances of the measured currents enter filtered to the motor model and thus the calculated
model
current and the current control are smoother. The disadvantage is in the danger that the drive could change
to OC when there is a difference between measured and calculated current. Thus pay special attention to the
identification of the equivalent circuit
data.
Observer:
The observer (dS.18 bit5) adjusts the model currents dependent on the measured currents by the adjusted
factor in parameter dS.23 „observer factor".
Square-law load torque characteristic:
If the drive shall be accelerated at torque limit, it is mandatory necessary that the max. breakdown torque is not
exceeded. For this parameter (dS.03 bit 1) must be activated and the breakdown torque must be entered at
corner speed (dr.18) in parameter dr.16.
The corner speed (dr.18) should be set to rated speed (dr.01). If the breakdown torque should not be arise from
the data sheet, the breakdown torque must be calculated from the equivalent circuit data.
Rough formula : Mk = 2.0 * Mn
Mk = breakdown torque (dr.16)
Mn = rated torque (dr.14)
Содержание COMBIVERT F5-A
Страница 1: ...KEB COMBIVERT F5 A E H 4 4 APPLICATION MANUAL Mat No Rev 00F5AEA K440 1A...
Страница 2: ...Page 1 1 2 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Страница 4: ...Page 1 1 4 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Страница 14: ...Page 1 1 14 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Страница 20: ...Page 2 1 6 COMBIVERT F5 A E H KEB 2012 10 Product Overview...
Страница 28: ...Page 3 1 8 COMBIVERT F5 A E H KEB 2012 10 Control Units...
Страница 34: ...Page 4 1 6 COMBIVERT F5 A E H KEB 2012 10 Fundamentals...
Страница 40: ...Page 4 2 6 COMBIVERT F5 A E H KEB 2012 10 Password input...
Страница 42: ...Page 5 1 2 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Страница 46: ...Page 5 1 6 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Страница 70: ...Page 6 2 20 COMBIVERT F5 A E H KEB 2012 10 Start up...
Страница 140: ...Page 7 3 44 COMBIVERT F5 A E H KEB 2012 10 Digital in and outputs...
Страница 200: ...Page 7 5 38 COMBIVERT F5 A E H KEB 2012 10 Motor data and controller adjustments of the asynchronous motor...
Страница 207: ...Motor data and controller adjustments of the synchronous motor KEB 2012 10 COMBIVERT F5 A E H Page 7 6 7 7...
Страница 238: ...Page 7 7 12 COMBIVERT F5 A E H KEB 2012 10 Speed control...
Страница 254: ...Page 7 8 16 COMBIVERT F5 A E H KEB 2012 10 Torque display and limiting...
Страница 260: ...Page 7 9 6 COMBIVERT F5 A E H KEB 2012 10 Torque control...
Страница 292: ...Page 7 11 26 COMBIVERT F5 A E H KEB 2012 10 Speed measurement...
Страница 432: ...Page 7 14 14 COMBIVERT F5 A E H KEB 2012 10 Parameter sets...
Страница 466: ...Page 7 15 34 COMBIVERT F5 A E H KEB 2012 10 Special functions...
Страница 478: ...Page 7 16 12 COMBIVERT F5 A E H KEB 2012 10 CP Parameter definition...
Страница 480: ...Page 8 1 2 COMBIVERT F5 A E H KEB 2012 10 Troubleshooting 8 1 1 General 8 1 3 8 1 2 Error Messages and their Cause 8 1 3...
Страница 488: ...Page 8 1 10 COMBIVERT F5 A E H KEB 2012 10 Troubleshooting...
Страница 496: ...Page 9 1 8 COMBIVERT F5 A E H KEB 2012 10 General design...
Страница 538: ...Page 11 1 28 COMBIVERT F5 A E H KEB 2012 10 Parameter...
Страница 540: ...Page 12 1 2 COMBIVERT F5 A E H KEB 2008 02 Annex 12 1 1 Index 12 1 3...