Posi- and synchronous operating
© KEB, 2012-10
COMBIVERT F5-A, -E, -H
Page 7.12 - 59
7
Start positioning
Activation positioning/ synchro-
nous
7.12.4.13 Posi mode / flying referencing with correction
During the round table positioning with only one encoder for motor and round table position, a flying referencing
for correcting a gear factor error exists. For other applications using only one encoder, one needs compensati-
on for slip (undercarriages) or cable stretch (hoists).
An undercarriage shall, e.g., be moved 1m, corresponding to 10,000 increments. During starting, the powered
wheels slip on the steel rail, however, so that after 10,000 increments of encoder revolution, the undercarriage
has only travelled 0.95m.
To compensate for this error, the slip-afflicted system can be resynchronised via reference markers. There re
-
ference markers indicate the real position of the drive. An adjustment value is calculated from this information.
The adjustment is still carried out within one active positioning, to reach the target at the predefined position.
To be able to approach the target from both directions, two reference markers that can be located at different
positions must be supported.
Dependent on the direction of rotation, the positive edge of the reference marker is expected at a distance
to target of PS.46 "relative adjustment switch clockwise rotation" (direction of rotation clockwise) and PS.47
"relative adjustment switch counter clockwise rotation" (direction of rotation counter clockwise), respectively.
In parameter ru.69 "distance ref.-zero point", the adjustment value is displayed. It is calculated as:
Clockwise rotation: ru.69 = PS.46 - (ru.61: target position - ru.56: set position)
Counter clockwise rotation: ru.69 = (ru.61: target position – ru.56: set position) - PS.47
Example:
Un undercarriageshall drive to the position 5m (= 5,000 increments).
The undercarriage loses 02m (= 200 increments) during acceleration due to slip.
The right reference marker is situated at position 4...4.3m => PS.46 = 1m = 1,000.
The left reference marker is situated at position 5.2...5.5m => PS.47 = 0.5m = 500.
Clockwise rotation:
Counter clockwise rotation:
Содержание COMBIVERT F5-A
Страница 1: ...KEB COMBIVERT F5 A E H 4 4 APPLICATION MANUAL Mat No Rev 00F5AEA K440 1A...
Страница 2: ...Page 1 1 2 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Страница 4: ...Page 1 1 4 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Страница 14: ...Page 1 1 14 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Страница 20: ...Page 2 1 6 COMBIVERT F5 A E H KEB 2012 10 Product Overview...
Страница 28: ...Page 3 1 8 COMBIVERT F5 A E H KEB 2012 10 Control Units...
Страница 34: ...Page 4 1 6 COMBIVERT F5 A E H KEB 2012 10 Fundamentals...
Страница 40: ...Page 4 2 6 COMBIVERT F5 A E H KEB 2012 10 Password input...
Страница 42: ...Page 5 1 2 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Страница 46: ...Page 5 1 6 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Страница 70: ...Page 6 2 20 COMBIVERT F5 A E H KEB 2012 10 Start up...
Страница 140: ...Page 7 3 44 COMBIVERT F5 A E H KEB 2012 10 Digital in and outputs...
Страница 200: ...Page 7 5 38 COMBIVERT F5 A E H KEB 2012 10 Motor data and controller adjustments of the asynchronous motor...
Страница 207: ...Motor data and controller adjustments of the synchronous motor KEB 2012 10 COMBIVERT F5 A E H Page 7 6 7 7...
Страница 238: ...Page 7 7 12 COMBIVERT F5 A E H KEB 2012 10 Speed control...
Страница 254: ...Page 7 8 16 COMBIVERT F5 A E H KEB 2012 10 Torque display and limiting...
Страница 260: ...Page 7 9 6 COMBIVERT F5 A E H KEB 2012 10 Torque control...
Страница 292: ...Page 7 11 26 COMBIVERT F5 A E H KEB 2012 10 Speed measurement...
Страница 432: ...Page 7 14 14 COMBIVERT F5 A E H KEB 2012 10 Parameter sets...
Страница 466: ...Page 7 15 34 COMBIVERT F5 A E H KEB 2012 10 Special functions...
Страница 478: ...Page 7 16 12 COMBIVERT F5 A E H KEB 2012 10 CP Parameter definition...
Страница 480: ...Page 8 1 2 COMBIVERT F5 A E H KEB 2012 10 Troubleshooting 8 1 1 General 8 1 3 8 1 2 Error Messages and their Cause 8 1 3...
Страница 488: ...Page 8 1 10 COMBIVERT F5 A E H KEB 2012 10 Troubleshooting...
Страница 496: ...Page 9 1 8 COMBIVERT F5 A E H KEB 2012 10 General design...
Страница 538: ...Page 11 1 28 COMBIVERT F5 A E H KEB 2012 10 Parameter...
Страница 540: ...Page 12 1 2 COMBIVERT F5 A E H KEB 2008 02 Annex 12 1 1 Index 12 1 3...