The number the increments per motor revolution is calculated as:
"encoder increments per revolution" * 2 "multiple evaluation" x "gear factor denominator" / "gear factor nume-
rator"
The number of increments per load revolution for application 2 is equal to:
"encoder increments per revolution" * 2 "multiple evaluation".
The encoder should always be connected to channel 1, since the software for this channel optimally supports
the motor encoder connection via gear. Parameter Ec.39 „enc. 1 over transmission“ must be set to value „1:
motor encoder“. (For further functions and settings of Ec.39 see chapter 7.11)
Example (application 1):
Encoder channel 1: Encoder with 32 SIN / COS signals per revolution
Gear ratio:
Motor to encoder = 3 encoder revolutions correspond to motor revolution = 1 to 3
cS.01:
Actual source (= PS.01)
= 0
Channel 1
Ec.01:
encoder 1 (inc/r)
= 32
number SIN / COS signals
Ec.07:
Enc. 1 trigger
= 9
512-fold evaluation of the analog tracks
Ec.04:
Gear 1 numerator
= 1000
Gear factor 0.333
Ec.05:
Gear 1 denominator
= 3000
Ec.39:
Encoder 1 over gear
= 1
Encoder mounting via gear
The motor shall travel 5.5 revolutions:
→ 32 x 2
9
x 3000 / 1000 x 5.5 = 270336 increments
Example (application 2):
Encoder channel 1: SSI encoder multiturn with 12bit resolution per revolution and 12bit multiturn
Gear ratio:
Motor to encoder = 5 motor revolutions correspond to motor revolution = 5 to 1
cS.01:
Actual source (= PS.01)
= 0
Channel 1
Ec.01:
encoder 1 (inc/r)
= 1024
12-bit resolution per revolution
Ec.07:
Enc. 1 trigger
= 2
Multiple evaluation with SSI encoder always = 2
Ec.53
Encoder 1 SSI multiturn.
= 12
12 bit Multiturn-resolution
Ec.04:
Gear 1 numerator
= 1000
Gear factor 0.333
Ec.05:
Gear 1 denominator
= 3000
Ec.39:
Encoder 1 over gear
= 1
Encoder mounting via gear
The load shall travel 5.5 revolutions:
→ 1024 x 2
2
x 5.5 = 22628 increments
The operation of synchronous motors is not supported and the position normalisation is as follows:
The number of increments per motor revolution is calculated as:
Posi- and synchronous operating
© KEB, 2012-10
COMBIVERT F5-A, -E, -H
Page 7.12 - 33
7
Содержание COMBIVERT F5-A
Страница 1: ...KEB COMBIVERT F5 A E H 4 4 APPLICATION MANUAL Mat No Rev 00F5AEA K440 1A...
Страница 2: ...Page 1 1 2 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Страница 4: ...Page 1 1 4 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Страница 14: ...Page 1 1 14 COMBIVERT F5 A E H KEB 2008 02 Table of contents...
Страница 20: ...Page 2 1 6 COMBIVERT F5 A E H KEB 2012 10 Product Overview...
Страница 28: ...Page 3 1 8 COMBIVERT F5 A E H KEB 2012 10 Control Units...
Страница 34: ...Page 4 1 6 COMBIVERT F5 A E H KEB 2012 10 Fundamentals...
Страница 40: ...Page 4 2 6 COMBIVERT F5 A E H KEB 2012 10 Password input...
Страница 42: ...Page 5 1 2 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Страница 46: ...Page 5 1 6 COMBIVERT F5 A E H KEB 2012 10 Selection of Operating Mode...
Страница 70: ...Page 6 2 20 COMBIVERT F5 A E H KEB 2012 10 Start up...
Страница 140: ...Page 7 3 44 COMBIVERT F5 A E H KEB 2012 10 Digital in and outputs...
Страница 200: ...Page 7 5 38 COMBIVERT F5 A E H KEB 2012 10 Motor data and controller adjustments of the asynchronous motor...
Страница 207: ...Motor data and controller adjustments of the synchronous motor KEB 2012 10 COMBIVERT F5 A E H Page 7 6 7 7...
Страница 238: ...Page 7 7 12 COMBIVERT F5 A E H KEB 2012 10 Speed control...
Страница 254: ...Page 7 8 16 COMBIVERT F5 A E H KEB 2012 10 Torque display and limiting...
Страница 260: ...Page 7 9 6 COMBIVERT F5 A E H KEB 2012 10 Torque control...
Страница 292: ...Page 7 11 26 COMBIVERT F5 A E H KEB 2012 10 Speed measurement...
Страница 432: ...Page 7 14 14 COMBIVERT F5 A E H KEB 2012 10 Parameter sets...
Страница 466: ...Page 7 15 34 COMBIVERT F5 A E H KEB 2012 10 Special functions...
Страница 478: ...Page 7 16 12 COMBIVERT F5 A E H KEB 2012 10 CP Parameter definition...
Страница 480: ...Page 8 1 2 COMBIVERT F5 A E H KEB 2012 10 Troubleshooting 8 1 1 General 8 1 3 8 1 2 Error Messages and their Cause 8 1 3...
Страница 488: ...Page 8 1 10 COMBIVERT F5 A E H KEB 2012 10 Troubleshooting...
Страница 496: ...Page 9 1 8 COMBIVERT F5 A E H KEB 2012 10 General design...
Страница 538: ...Page 11 1 28 COMBIVERT F5 A E H KEB 2012 10 Parameter...
Страница 540: ...Page 12 1 2 COMBIVERT F5 A E H KEB 2008 02 Annex 12 1 1 Index 12 1 3...